variable speed drive, Easy Altivar 610, 0.75kW, 1hp, 380 to 460V, IP20

variable speed drive, Easy Altivar 610, 0.75kW, 1hp, 380 to 460V, IP20

0 reviews 0 sold. Only 1 remain
0.00ريال
Product Code: ATV610U07N4
Availability: In Stock
Viewed 677 times

Product Description


This Easy Altivar 610 drive is a frequency inverter for three-phase asynchronous motors. It works at a rated supply voltage from 380V to 415V AC. It is suitable for motors with power rating up to 0.75kW / 1hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 0.37kW / 0.5hp for applications requiring significant overload (up to 150%). It offers a plug & play solution, whereby parameters are preset in the factory to the desired configuration, to help save process control and operating time. It has integrated radio interference input filters in accordance with the EMC standard for variable speed electrical power drive “products” IEC/EN 61800-3, edition 2, category C3 in environment 1 or 2. It weighs 2.4kg and its dimensions are, 145mm wide, 297mm high, 203mm deep. this drive has been specially designed for standard applications in the market segments water and wastewater and oil and gas and in the domains process and machine management and building management.

Item specifics

  • Main

  • Continuous output current 2.2 A at 4 kHz for normal duty 1.5 A at 4 kHz for heavy duty
  • Device short name ATV610
  • Nominal switching frequency 4 kHz
  • number of preset speeds 16 preset speeds
  • Output frequency 0.1…500 Hz
  • Prospective line Isc 5 kA
  • Switching frequency 2...12 kHz adjustable
  • Type of cooling Forced convection
  • Variant Standard version
  • Range of product Easy Altivar 610
  • Product or component type Variable speed drive
  • Product specific application Fan, pump, compressor, conveyor
  • mounting mode Cabinet mount
  • Communication port protocol Modbus serial
  • Supply frequency 50...60 Hz +/-5 %
  • [Us] rated supply voltage 380...460 V - 15...10 %
  • Motor power hp 1 hp for normal duty 0.5 hp for heavy duty
  • Motor power kW 0.75 kW for normal duty 0.37 kW for heavy duty
  • EMC filter Integrated conforming to IEC 61800-3 category C3 with 50 m
  • IP degree of protection IP20
  • Product destination Asynchronous motors Synchronous motors
  • Network number of phases 3 phases
  • Line current 3.1 A at 380 V (normal duty) 2.6 A at 460 V (normal duty) 1.7 A at 380 V (heavy duty) 1.4 A at 460 V (heavy duty)
  • Apparent power 2.1 kVA at 460 V (normal duty) 1.1 kVA at 460 V (heavy duty)
  • Maximum transient current 2.4 A during 60 s (normal duty) 2.3 A during 60 s (heavy duty)
  • Asynchronous motor control profile Constant torque standard Optimized torque mode Variable torque standard
  • Option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
  • Complementary

  • Acceleration and deceleration ramps S, U or customized Linear adjustable separately from 0.01 to 9000 s
  • Accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
  • Analogue input number 3
  • Analogue input type AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
  • Analogue output number 2
  • Analogue output type Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits
  • Braking to standstill By DC injection
  • Connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
  • Depth 203 mm
  • Discrete input logic Positive logic (source): DI1...DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1...DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
  • Discrete input number 6
  • Discrete input type DI1...DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
  • Electrical connection Control, screw terminal: 0.5...1.5 mm² Line side, screw terminal: 2.5...16 mm² Motor, screw terminal: 2.5...16 mm²
  • Frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
  • Height 297 mm 350 mm with EMC plate
  • Input compatibility DI1...DI6: logic input level 1 PLC conforming to IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
  • Insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
  • Isolation Between power and control terminals
  • Linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
  • Local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
  • Maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
  • Method of access Slave
  • Minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
  • Motor slip compensation Not available in permanent magnet motor law Adjustable Automatic whatever the load Can be suppressed
  • Net weight 3.135 kg
  • Number of addresses 1…247 for Modbus serial
  • Output voltage <= power supply voltage
  • Physical interface 2-wire RS 485 for Modbus serial
  • Protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
  • Refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
  • Relay output number 3
  • Relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
  • Sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input 2 ms +/- 0.5 ms (DI1...DI6)configurable - discrete input 5 ms +/- 1 ms (DI5, DI6)configurable - pulse input 10 ms +/- 1 ms (AQ1, AQ2) - analog output
  • Supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
  • Transmission frame RTU for Modbus serial
  • Transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
  • Type of polarization No impedance for Modbus serial
  • Width 145 mm
  • Environment

  • Ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
  • Electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
  • Environmental characteristic Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3
  • marking CE
  • Noise level 55 dB conforming to 86/188/EEC
  • Operating altitude <= 1000 m without derating 1000...4800 m with current derating 1 % per 100 m
  • Operating position Vertical +/- 10 degree
  • Pollution degree 2 conforming to IEC 61800-5-1
  • Power dissipation in W 19 W(forced convection) at 380 V, switching frequency 4 kHz 23 W(natural convection) at 380 V, switching frequency 4 kHz
  • Relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
  • Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
  • Standards IEC 61800-3 Environment 2 category C3 IEC 61800-3 IEC 61800-5-1 IEC 60721-3
  • Vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
  • Packing Units

  • Number of Units in Package 1 1
  • Number of Units in Package 2 6
  • Package 1 Height 19.000 cm
  • Package 1 Length 40.500 cm
  • Package 1 Weight 4.245 kg
  • Package 1 Width 30.500 cm
  • Package 2 Height 75.000 cm
  • Package 2 Length 80.000 cm
  • Package 2 Weight 33.470 kg
  • Package 2 Width 60.000 cm
  • Unit Type of Package 1 PCE