variable speed drive, Easy Altivar 310, heavy duty, 0.75kW, 1hp, 380 to 460V, without EMC
- Training
- Industrial Automation and Control
-
Low voltage protection devices
-
Motor protection devices
- Contactors & Reversing Contactors - EasyPact TVS
- Contactors & Reversing Contactors - TeSys D
- Contactors & Reversing Contactors - TeSys D capacitor
- Contactors & Reversing Contactors - TeSys F
- Contactors & Reversing Contactors - TeSys Giga
- Contactors & Reversing Contactors - TeSys K
- Contactors & Reversing Contactors - TeSys LE
- Electronic Over Current Relays - Easy TeSys Protect
- Electronic Overload Relays - EOCR
- Motor management system - TeSys island
- Motor protection circuit breakers - Easy TeSys Power GZ
- Motor protection circuit breakers - TeSys GV2
- Motor protection circuit breakers - TeSys GV3
- Motor protection circuit breakers - TeSys GV4
- Thermal Overload Relays - TeSys Giga
- Thermal Overload Relays - TeSys LR9
- Thermal Overload Relays - TeSys LRD
- Relays and industrial accessories
-
Circuit Breakers and Switches
- Air Circuit Breakers - EasyPact MVS
- Air Circuit Breakers - MasterPact MTZ
- Air Circuit Breakers - MasterPact NW
- Miniature Circuit Breakers - Acti 9 C120
- Miniature Circuit Breakers - Acti 9 iC60
- Miniature Circuit Breakers - Acti 9 iK60
- Miniature Circuit Breakers - Residental Domae
- Miniature Circuit Breakers - Residental Resi9
- Molded Case Circuit Breakers - ComPacT INS
- Molded Case Circuit Breakers - ComPacT NS
- Molded Case Circuit Breakers - ComPacT NSX
- Molded Case Circuit Breakers - Easy CVS
- Molded Case Circuit Breakers - Easy GoPact
- Molded Case Circuit Breakers - Easy GoPact MTS
- Residual current devices - Acti 9 iC60 RCBO
- Residual current devices - Acti 9 iID RCCB
- Residual current devices - Vigi for iC60
- Power Quality and Power Factor Correction
-
Motor protection devices
-
Power supplies & Energy monitoring system
-
Energy meters & supplies
- Advanced metering
- Current Transformers
- EasyLogic DM6000H series VAF PF meters
- EasyLogic PM2000 Power Meters
- Industrial Power supplies - (ABLM / ABLS / ABL8)
- PowerLogic PM3000 Power Meters
- PowerLogic PM5000 Power Meters
- Single phase power supplies - Easy Modicon ABL2
- Temperature controller
- Transformers - Modicon ABT7, ABL6
-
Energy meters & supplies
- Control station & joysticks
- Secure Power
- Enclosures
Your shopping cart is empty!
Product Description
This Easy Altivar 310 drive is a frequency inverter for three-phase asynchronous motors. Its protection index is IP20. It works at a rated power up to 0.75kW/1HP, and a rated voltage from 380V to 460V AC. Its compact size, robust design and ease of installation, based on the principle of plug and play and its integrated functions make it particularly suitable for applications involving industrial machines and certain consumer machines. It offers high readability of key parameters thanks to a bright LED 4-digit display. Underload and overload detection help to protect your installation. It weighs 0.8kg and its dimensions are, 72mm wide, 143mm high, 140mm deep. This drive incorporates functions that are suitable for the most common applications, including textile machine, machine tools, wood making machine, material handling, packaging and printing machines, ceramic machine.
Item specifics
-
Main
- Device short name ATV310
- Range of product Easy Altivar 310
- Product or component type Variable speed drive
- Product specific application Simple machine
- [Us] rated supply voltage 380...460 V - 15...10 %
- Motor power hp 1 hp for heavy duty
- Motor power kW 0.75 kW for heavy duty
- Assembly style With heat sink
- Network number of phases Three phase
-
Complementary
- Acceleration and deceleration ramps Linear from 0...999.9 s S U
- Analogue input number 1
- Analogue input type Configurable current AI1 0...20 mA 250 Ohm Configurable voltage AI1 0...10 V 30 kOhm Configurable voltage AI1 0...5 V 30 kOhm
- Analogue output number 1
- Analogue output type AO1 software-configurable voltage: 0...10 V AC 0...10 V 0…0.02 A, impedance: 470 Ohm, resolution 8 bits AO1 software-configurable current: 0...20 mA, impedance: 800 Ohm, resolution 8 bits
- Apparent power 2.5 kVA at 460 V (heavy duty)
- Asynchronous motor control profile Voltage/frequency ratio (V/f) Voltage/frequency ratio - Energy Saving, quadratic U/f Sensorless vector control (SVC)
- Braking to standstill By DC injection, <30 s
- Braking torque Up to 70 % of nominal motor torque without braking resistor
- Communication port protocol Modbus
- Communication service Read holding registers (03) 29 words Write single register (06) 29 words Write multiple registers (16) 27 words Read/write multiple registers (23) 4/4 words Read device identification (43)
- Connector type RJ45 (on front face) for Modbus
- Continuous output current 2.3 A heavy duty
- Depth 140 mm
- Discrete input logic Negative logic (sink), > 16 V (state 0), < 10 V (state 1), input impedance 3.5 kOhm Positive logic (source), 0...< 5 V (state 0), > 11 V (state 1)
- Discrete input number 4
- Discrete input type Programmable LI1...LI4 24 V 18...30 V
- Discrete output number 2
- Discrete output type Logic output LO+, LO- Protected relay output R1A, R1B, R1C 1 C/O
- Electrical connection Terminal, clamping capacity: 1.5...2.5 mm², AWG 16...AWG 14 (L1, L2, L3, U, V, W)
- EMC filter Without EMC filter
- Frequency resolution Analog input: converter A/D, 10 bits Display unit: 0.1 Hz
- Height 143 mm
- Insulation Electrical between power and control
- Line current 3.5 A at 380 V (heavy duty) 3.1 A at 460 V (heavy duty)
- Linearity error +/- 0.3 % of maximum value for analogue input
- Maximum switching current 2 A at 250 V AC on inductive load cos phi = 0.4 L/R = 7 ms for logic relay 2 A at 30 V DC on inductive load cos phi = 0.4 L/R = 7 ms for logic relay 3 A at 250 V AC on resistive load cos phi = 1 L/R = 0 ms for logic relay 4 A at 30 V DC on resistive load cos phi = 1 L/R = 0 ms for logic relay
- Maximum transient current 3.5 A during 60 s (heavy duty)
- Minimum switching current 5 mA at 24 V DC for logic relay
- Motor slip compensation Adjustable
- Net weight 0.8 kg
- Nominal switching frequency 4 kHz
- Number of addresses 1…247 for Modbus
- Operating position Vertical +/- 10 degree
- Output voltage 380...460 V three phase
- Physical interface 2-wire RS 485 for Modbus
- Power dissipation in W 34.1 W, at In (heavy duty)
- Product destination Asynchronous motors
- Prospective line Isc 5 kA ( heavy duty )
- Protection type Line supply overvoltage Line supply undervoltage Overcurrent between output phases and earth Overheating protection Short-circuit between motor phases Against input phase loss in three-phase Thermal motor protection via the drive by continuous calculation of I²t
- Quantity per set Set of 1
- Sampling duration 10 ms for analogue input 20 ms, tolerance +/- 1 ms for logic input
- Speed drive output frequency 0.5…400 Hz
- Speed range 1…20 for asynchronous motor
- Supply Internal supply for reference potentiometer: 5 V (4.75…5.25 V)DC, <10 mA with overload and short-circuit protection Internal supply for logic inputs: 24 V (20.4…28.8 V)DC, <100 mA with overload and short-circuit protection
- Supply frequency 50/60 Hz +/- 5 %
- Switching frequency 2...12 kHz adjustable
- Tightening torque 0.8…1 N.m
- Time constant 20 ms +/- 1 ms for reference change
- Transient overtorque 170…200 % of nominal motor torque depending on drive rating and type of motor
- Transmission frame RTU for Modbus
- Transmission rate 4800 bit/s 9600 bit/s 19200 bit/s 38400 bit/s
- Type of cooling Self-cooled
- Width 72 mm
-
Environment
- Ambient air temperature for operation -10…55 °C without derating 55…60 °C protective cover from the top of the drive removed with current derating 2.2 % per °C
- Ambient air temperature for storage -25…70 °C
- Electromagnetic compatibility Electrical fast transient/burst immunity test - test level: level 4 conforming to IEC 61000-4-4 Electrostatic discharge immunity test - test level: level 3 conforming to IEC 61000-4-2 Immunity to conducted disturbances - test level: level 3 conforming to IEC 61000-4-6 Radiated radio-frequency electromagnetic field immunity test - test level: level 3 conforming to IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 Surge immunity test - test level: level 3 conforming to IEC 61000-4-5
- Environmental characteristic Dust pollution resistance class 3S2 conforming to IEC 60721-3-3 Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3
- IP degree of protection IP20 without blanking plate on upper part IP4X top
- Operating altitude <= 1000 m without derating
- Pollution degree 2 conforming to IEC 61800-5-1
- Product certifications CE EAC KC
- Relative humidity 5…95 % without condensation conforming to IEC 60068-2-3 5…95 % without dripping water conforming to IEC 60068-2-3
- Shock resistance 15 gn conforming to IEC 60068-2-27 for 11 ms
- Standards IEC 61800-5-1
-
Packing Units
- Number of Units in Package 1 1
- Number of Units in Package 2 39
- Package 1 Height 13.21 cm
- Package 1 Length 19.3 cm
- Package 1 Weight 1.06 kg
- Package 1 Width 19.05 cm
- Package 2 Height 74 cm
- Package 2 Length 80 cm
- Package 2 Weight 50.95 kg
- Package 2 Width 60 cm
- Unit Type of Package 1 PCE
- Unit Type of Package 2 S06