Altivar Soft Starter ATS480 is intended to start and stop asynchronous motors supplied from 208V to 690V. It meets the requirements of the most demanding applications in normal and heavy duty. With an operational rated current of 17A in normal duty, it supplies motor from 4kW to 15kW according to mains voltage. Designed for digitization, connected, optimized to meet cybersecurity standard, it simplifies project execution and maximizes the availability of applications. Its torque control (TCS) masters acceleration and deceleration. It efficiently stops high inertia application thanks to the dynamic braking and DC injection. It could be connected in-line or inside the delta to reduce its operational current. The embedded test routine simplifies the commissioning inside the delta. Its dimensions are 160mm (width) x 203mm (depth) x 275mm (height) and it weighs 4,9kg. Altivar Soft Starter ATS480 is designed to address process, infrastructures and industrial machines. It conforms to IEC/EN60947-4-1. It is certified CE, cULus, UKCA, CCC, RCM, EAC, and Marine certified DNV, ABS, BV and CCS. Display terminals, remote mounting kit, communication modules are common with Altivar Drives. Line chokes, DNV kits are common with ATS48. ATS480 is compatible with ATS48, it has same footprint, fixing, torque control algorithm, I/O, menus… The integration of Altivar Soft Starter ATS480 in EcoStruxure drastically simplifies architecture selection, detailed design and execution in automation and electrical systems. It is a Green Premium product designed to take the environmental considerations beyond current directives and regulations, compliant with RoHS and REACH.

Item specifics

  • Main

  • Device short name ATS480
  • Maximum Horse Power Rating 3.0 hp 208 V normal duty 2.0 hp 208 V heavy duty 5.0 hp 230 V normal duty 3.0 hp 230 V heavy duty 10.0 hp 460 V normal duty 7.5 hp 460 V heavy duty 15.0 hp 575 V normal duty 10.0 hp 575 V heavy duty
  • Phase 3 phase
  • power supply frequency 50...60 Hz - 20...20 %
  • rated current in heavy duty 12.0 A at 104 °F (40 °C) heavy duty
  • Torque control True
  • Ue power supply voltage 208...690 V - 15...10 %
  • Utilisation category AC-3A AC-53A
  • [Ie] rated operational current Normal duty 17.0 A 104 °F (40 °C))
  • Range of product Altivar Soft Starter ATS480
  • Product or component type Soft starter
  • Product specific application Process and infrastructures
  • Motor power kW 4.0 kW 230 V in the motor supply line normal duty 2.2 kW 230 V in the motor supply line heavy duty 7.5 kW 400 V in the motor supply line normal duty 5.5 kW 400 V in the motor supply line heavy duty 7.5 kW 440 V in the motor supply line normal duty 5.5 kW 440 V in the motor supply line heavy duty 9.0 kW 500 V in the motor supply line normal duty 7.5 kW 500 V in the motor supply line heavy duty 9.0 kW 525 V in the motor supply line normal duty 7.5 kW 525 V in the motor supply line heavy duty 11.0 kW 660 V in the motor supply line normal duty 9.0 kW 660 V in the motor supply line heavy duty 15.0 kW 690 V in the motor supply line normal duty 11.0 kW 690 V in the motor supply line heavy duty 7.5 kW 230 V to the motor delta terminals normal duty 5.5 kW 230 V to the motor delta terminals heavy duty 15.0 kW 400 V to the motor delta terminals normal duty 11.0 kW 400 V to the motor delta terminals heavy duty
  • IP degree of protection IP20
  • Product destination Asynchronous motors
  • Option card Communication module Profibus DP V1 Communication module Modbus TCP/EtherNet/IP Communication module CANopen daisy chain Communication module CANopen Sub-D Communication module CANopen open style
  • Complementary

  • Analogue input number 1
  • Analogue input type AI1/PTC PTC/Pt 100 temperature probe PTC2 PTC/Pt 100 temperature probe PTC3 PTC/Pt 100 temperature probe
  • Analogue output number 1
  • Analogue output type Current output AQ1 0...20 mA or 0...10 V 500 Ohm
  • Apparent power 0.06 kVA
  • Communication data link Serial
  • Communication port protocol Modbus serial
  • Connector type 1 RJ45
  • current limiting %In (5 x Ie maximum) 150…700 %
  • Data format 8 bits, configurable odd, even or no parity
  • Depth 8.0 in (203.0 mm)
  • Device connection In the motor supply line To the motor delta terminals
  • Discrete input logic Programmable digital input < 5 V
  • Discrete input number 4
  • Discrete input type STOP) logic inputs, 3500 Ohm RUN) logic inputs, 3500 Ohm DI3) programmable as logic input, 3500 Ohm DI4) programmable as logic input, 3500 Ohm
  • Discrete output number 2
  • Discrete output type DQ1) programmable digital output <= 30 V DQ2) programmable digital output <= 30 V
  • Display screen available True
  • Function Available External bypass control Pre-heating Smoke extraction Multi-motor cascade Second motor set User management Ports and services hardening Security event logging Cybersecure firmware update Single direction
  • Height 10.8 in (275.0 mm)
  • Input compatibility STOP discrete input level 1 PLC IEC 61131-2 RUN discrete input level 1 PLC IEC 61131-2 DI3 discrete input level 1 PLC IEC 61131-2 DI4 discrete input level 1 PLC IEC 61131-2
  • Integrated motor overload protection True
  • marking CE CCC UKCA EAC RCM CULus
  • Maximum switching current Relay outputs 2 A 250 V AC Relay outputs 2 A 30 V DC
  • Method of access Slave Modbus serial
  • Minimum switching current 100 mA 12 V DC relay outputs
  • motor thermal protection class Class 10E
  • Net weight 10.8 lb(US) (4.9 kg)
  • Number of addresses 0…227 Modbus serial
  • Operating position Vertical +/- 10 degree
  • Output compatibility Open collector level 1 PLC IEC 65A-68
  • Physical interface 2-wire RS 485
  • Power loss per device current dependent 38.0 W
  • Power loss static current independent 25.0 W
  • Product Certifications CE cULus CCC UKCA RCM EAC DNV ABS BV CCS
  • Protection type Phase failure line Integrated thermal protection motor Thermal protection starter Current overload motor Underload motor Excessive starting time, locked rotor motor Motor phase loss motor Line supply phase loss line Line supply phase loss motor Thermal protection motor
  • Relay output number 3
  • Relay output type Relay outputs R1A 1 NO Relay outputs R1B 1 NO Relay outputs RIC NO/NC programmable
  • Standards IEC 60947-4-2 UL 60947-4-2 IEC 60664-1
  • Transmission frame RTU
  • Transmission rate 1200...256000 bit/s
  • Type of polarization No impedance Modbus serial
  • Width 6.3 in (160.0 mm)
  • [In] Rated current pwr loss specifctn 17.0 A
  • [Uc] control circuit voltage 24 V DC
  • [Us] control circuit voltage 110...230 V AC 50/60 Hz - 15...10 %
  • Environment

  • Ambient air temperature for operation 104…140 °F (40…60 °C) with current derating of 2 % per °C) 5…104 °F (-15…40 °C) without derating)
  • Ambient air temperature for storage -13…158 °F (-25…70 °C)
  • Electromagnetic compatibility Conducted and radiated emissions level A IEC 60947-4-2 Conducted and radiated emissions with bypass level B IEC 60947-4-2 Damped oscillating waves level 3 IEC 61000-4-12 Electrostatic discharge level 3 IEC 61000-4-11 Immunity to electrical transients level 4 IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3 Voltage/current impulse level 3 IEC 61000-4-5
  • Environmental class (during operation) Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3
  • Maximum acceleration under shock impact (during operation) 150 m/s² at 11 ms
  • Maximum acceleration under shock load (during storage) 100 m/s² at 11 ms
  • Maximum acceleration under shock load (during transport) 100 m/s² at 11 ms
  • Maximum acceleration under vibrational stress (during operation) 10 m/s² at 13...200 Hz
  • Maximum acceleration under vibratory load (during storage) 15 m/s² at 200...500 Hz 10 m/s² at 9...200 Hz
  • Maximum acceleration under vibratory load (during transport) 15 m/s² at 200...500 Hz 10 m/s² at 9...200 Hz
  • Maximum deflection under vibratory load (during operation) 1.5 mm at 2...13 Hz
  • Maximum deflection under vibratory load (during storage) 1.75 mm at 2...9 Hz
  • Maximum deflection under vibratory load (during transport) 1.75 mm at 2...9 Hz
  • Operating altitude <= 3280.84 ft (1000 m) without derating > 3280.84...13123.36 ft (> 1000...4000 m) with current derating 1 % per 100 m
  • Pollution degree Level 3
  • Relative humidity 0…95 % without condensation or dripping water IEC 60068-2-3
  • [Uimp] rated impulse withstand voltage 6 kV
  • [Ui] Rated Insulation Voltage 690 V
  • Packing Units

  • Number of Units in Package 1 1
  • Number of Units in Package 2 8
  • Package 1 Height 11.8 in (30 cm)
  • Package 1 Length 14.6 in (37 cm)
  • Package 1 Weight 13.704 lb(US) (6.216 kg)
  • Package 1 Width 11.02 in (28 cm)
  • Package 2 Height 29.5 in (75 cm)
  • Package 2 Length 31.5 in (80 cm)
  • Package 2 Weight 138.5 lb(US) (62.8 kg)
  • Package 2 Width 23.6 in (60 cm)
  • Unit Type of Package 1 PCE
  • Unit Type of Package 2 S06
  • Ordering and shipping details

  • Category US1CP1G22588
  • Country of origin CN
  • Discount Schedule CP1G
  • GTIN 3606481088994
  • Returnability Yes

Write a review

Note: HTML is not translated!
    Bad           Good
Soft starter, Altistart 480, 17A, 208 to 690V AC, control supply 110 to 230V AC

Soft starter, Altistart 480, 17A, 208 to 690V AC, control supply 110 to 230V AC

0.00ريال