PM3200 DIN mount energy meter with a 128 by 96 pixel backlit, LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 32 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor, Apparent Power and up to 15th Harmonic. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 277VAC, 173 to 480VAC and 100 to 300VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase, Single Phase and Neutral or Three Phase configurations. Direct measurement range is 50 to 570VAC, with an external VT 570 to 999000VAC. The range of measurement voltage between Phases is 80 to 570VAC at 45 to 65 Hz. Measurement range between Phase and Neutral is 50 to 330VAC at 45 to 65 Hz. This meter has no communication input or output capability. Product dimensions are as follows: width 3.54 in (90 mm), depth 2.76in (70 mm), height 3.74 in (95 mm) and product weight 9.17 oz (260 g).

Item specifics

  • Main

  • Device short name PM3200
  • Product name PowerLogic PM3000
  • Range PowerLogic
  • Product or component type Power meter
  • Complementary

  • Accuracy class Class 0.5S active energy conforming to IEC 62053-22 Class 1 active energy conforming to IEC 62053-21 Class 2 reactive energy conforming to IEC 62053-23 Class C active energy conforming to EN 50470-3
  • Analogue input type Current 0...5 A Current 0...1 A
  • Communication port protocol -
  • Communication port support -
  • Data recording Min/max of instantaneous values
  • Depth 70 mm
  • Device application Multi-tariff Sub billing Power monitoring
  • Display resolution 128 x 96 pixels
  • Display type Backlit LCD
  • Frequency measurement range 45…65 Hz
  • Height 95 mm
  • Information displayed Tariff (4)
  • Measurement accuracy Current 0.3 % 0.5...6 A Current 0.5 % 0.1...1.2 A Voltage 0.3 % 50...330 V Voltage 0.3 % 80...570 V
  • Measurement current 0.05…6 A 0.02…1.2 A
  • Measurement voltage 50…330 V AC 45...65 Hz direct 50…330 V AC 45...65 Hz phase to neutral 80…570 V AC 45...65 Hz direct 80…570 V AC 45...65 Hz phase to phase 570…999000 V AC 45...65 Hz with external VT
  • mounting mode Clip-on
  • Mounting support DIN rail
  • Net weight 0.26 kg
  • network frequency 50 Hz 60 Hz
  • Number of inputs 0
  • Number of outputs 0
  • Power consumption in VA 5 VA
  • Power quality analysis up to the 15th harmonic
  • Product Certifications CE conforming to IEC 61010-1 (safety) CE conforming to EN 61557-12 (power monitor) CE conforming to EN/IEC 61326-1 (EMC) UKCA conforming to BS EN 61010-1 (safety) UKCA conforming to BS EN 61557-12 (power monitor) UKCA conforming to BS EN 61326-1 (EMC) CULus conforming to EN 61010-1 (safety) CULus conforming to UL 61010-1 (safety) EAC (sub-meter) RCM
  • Sampling rate 32 samples/cycle
  • Standards BS EN 61557-12 IEC 61557-12 EN 61557-12 BS EN 61326-1 IEC 61326-1 EN 61326-1 BS EN 62052-11 IEC 62052-11 EN 62052-11 BS EN 62053-21 IEC 62053-21 EN 62053-21 BS EN 62053-22 IEC 62053-22 EN 62052-22 BS EN 62053-23 IEC 62053-23 EN 62052-23 BS EN 61010-1 EN 61010-1 IEC 61010-1 UL 61010-1 BS EN 61010-2-30 IEC 61010-2-30 EN 61010-2-30 UL 61010-2-30 ANSI C12.20
  • Supply voltage limits 100...277 V AC 45...65 Hz 173...480 V AC 45...65 Hz 100...300 V DC
  • Type of measurement Active and reactive power Apparent power Current Voltage Energy Power factor Frequency
  • type of network 3P + N 3P 1P + N
  • Width 90 mm
  • [In] rated current 5 A 1 A
  • Environment

  • Ambient air temperature for operation -25…70 °C
  • Ambient air temperature for storage -40…85 °C
  • Electromagnetic compatibility Electrostatic discharge level 4 conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 Surge immunity test level 4 conforming to IEC 61000-4-5 Conducted RF disturbances level 3 conforming to IEC 61000-4-6 Magnetic field at power frequency - test level: 0.5 mT conforming to IEC 61000-4-8 Conducted and radiated emissions class B conforming to EN 55022
  • IP degree of protection IP40 front panel: conforming to IEC 60529 IP20 body: conforming to IEC 60529
  • Operating altitude < 3000 m
  • Overvoltage category III
  • Pollution degree 2
  • Relative humidity 5…95 % at 50 °C
  • Packing Units

  • Number of Units in Package 1 1
  • Number of Units in Package 2 16
  • Number of Units in Package 3 128
  • Package 1 Height 8.8 cm
  • Package 1 Length 13.7 cm
  • Package 1 Weight 384 g
  • Package 1 Width 13.2 cm
  • Package 2 Height 30 cm
  • Package 2 Length 40 cm
  • Package 2 Weight 6.567 kg
  • Package 2 Width 30 cm
  • Package 3 Height 15 cm
  • Package 3 Length 120 cm
  • Package 3 Weight 57.672 kg
  • Package 3 Width 80 cm
  • Unit Type of Package 1 PCE
  • Unit Type of Package 2 S03
  • Unit Type of Package 3 P12
  • Contractual warranty

  • Warranty 18 months