PowerLogic ION7400 utility feeder power meters combine capabilities not typically available in compact meters. They offers a hight flexibility and usability, along with accurate 3-phase energy and power measurements with data logging. Use Power Monitoring Expert software for data analysis or share operation data with SCADA systems through multiple communication channels and protocols. Certified by third party labs for energy accuracy (IEC 62052-11, IEC 62052-22, IEC 62052-24) and power quality (IEC 62586-2, IEC 61000-4-30 Class S). Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol. Ability to enable/disable communication ports, and 16 user configurable accounts. With 512 MB of memory to support 50 data logs, 50+ user-definable alarms, waveform captures, 1/2 cycle RMS logging, custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 3 digital inputs and one digital output. I/O option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Wide control power range of 90-415 VAC / 110-415 VDC. Operating environment of -25 to +70C; Humidity rating of 5% to 95%; Altitude up to 3000 m. Panel mounting (1/4 DIN) with integrated display.

Item specifics

  • Main

  • Device short name ION7400
  • model type Standard
  • Product name PowerLogic ION7400
  • Range PowerLogic
  • Product or component type Power meter
  • Complementary

  • Accuracy class Class 0.2S active energy conforming to IEC 62053-22 Class 0.2 active energy conforming to ANSI C12.20 Class 0.2 active power conforming to IEC 61557-12 Class 0.5S reactive energy conforming to IEC 62053-24 Class 0.5 power factor conforming to IEC 61557-12 Class 0.2 voltage conforming to IEC 61557-12 Class 0.2 current conforming to IEC 61557-12 Class 0.2 frequency conforming to IEC 61557-12 Class 0.2 active energy conforming to IEC 61557-12
  • Analogue input type Voltage (impedance 5 MOhm) Current (impedance 0.3 mOhm)
  • Communication network type IPv6 (internet protocol)
  • Communication port protocol Modbus RTU at 115 kbauds - 2-wire ION at 115 kbauds - 2-wire DNP3 IEC 61850 Modbus TCP/IP Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s RSTP 801.1d 2004 Ansi C12.19 DLMS
  • Communication port support ETHERNET Screw terminal block: RS485 Optical probe: fiber optic Mini B USB: USB
  • Communication service DHCP RSTP support NTP time synchronization SMTP e-mail notification PTP time synchronization
  • Cybersecurity Syslog protocol support Robust security logs Enable/disable communication ports Password protection Port hardening
  • Data recording Alarm logs Waveform logs Sequence of event recording Event logs Sag and swell logs Data logs Harmonics logs GPS synchronisation Time stamping Trending/forecasting Min/max of instantaneous values 50 data recorders
  • Depth 78.5 mm
  • Device application Revenue billing WAGES metering Data aggregation Power monitoring
  • Display resolution 320 x 240 pixels QVGA
  • Display type Colour TFT LCD
  • Frequency measurement range 42…69 Hz
  • Height 112 mm
  • Information displayed Voltage Current Frequency Power Energy consumption Harmonic distortion
  • Installation category III
  • Measurement accuracy Current +/- 0.1 % Voltage +/- 0.1 % Active energy +/- 0.2 %
  • Measurement current 50…10000 mA
  • Measurement voltage 57…400 V AC 42...69 Hz between phase and neutral 100…690 V AC 42...69 Hz between phases
  • Memory capacity 512 MB
  • mounting mode Flush-mounted
  • Mounting support Framework
  • Net weight 706 g
  • network frequency 50 Hz 60 Hz
  • Number of inputs 3 digital 30 V AC 3 digital 60 V DC
  • Number of outputs 1 pulse
  • Poles description 1P + N 3P 3P + N
  • Power consumption in VA 18 VA at 415 V AC
  • Power quality analysis conforming to EN 50160: 2010 compliance report conforming to IEEE 519: 2014 compliance report conforming to IEC 61000-4-30: class S power quality measurement up to the 63rd harmonic harmonic distortion waveform capture voltage sag and swell detection programmablity (logic and math functions) conforming to IEC 62586 power quality monitoring conforming to IEC 61000-4-15 disturbance direction detection rapid voltage change
  • Product Certifications CE CULus N998
  • Safety Construction III400…690 V conforming to IEC 61010-1:ed. 3 III400…690 V conforming to EN 61010-1:ed. 3 III347…600 V conforming to UL 61010-1:ed. 3 III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3
  • Sampling rate 256 samples/cycle
  • Standards IEC 62053-22 IEC 62052-11 IEC 62053-24 IEC 61557-12 IEC 61326-1 IEEE 1588 IEC 62586
  • supply voltage 90...415 V AC 45...65 Hz +/- 10 % 110...415 V DC +/- 10 %
  • Type of installation Indoor installation
  • Type of measurement Current Voltage Frequency Active and reactive power total Apparent power total Power factor total Active and reactive power per phase, rms Apparent power per phase, rms Power factor per phase, rms Active and reactive energy Apparent energy
  • Web services Customizable home page File upload/download via FTP File upload/download via SFTP Web server Alarm notification by e-mail Viewing of captured waveform (FTP) Viewing of captured waveform (web) HTTPS server
  • Width 98 mm
  • [In] rated current 10 A 5 A 1 A
  • Environment

  • Ambient air temperature for operation -25…70 °C
  • Ambient air temperature for storage -40…85 °C
  • Electromagnetic compatibility Electrostatic discharge conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 Surge immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Magnetic field at power frequency conforming to IEC 61000-4-8 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 Immunity to impulse waves conforming to IEC 61000-4-12 Conducted and radiated emissions conforming to EN 55022 Conducted and radiated emissions conforming to EN 55011 Conducted and radiated emissions conforming to FCC part 15 Conducted and radiated emissions conforming to ICES-003 Conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579 Surge withstand conforming to IEEE C37.90.1
  • IP degree of protection IP54 front: conforming to IEC 60529 IP30 body: conforming to IEC 60529
  • Operating altitude 3000 m
  • Relative humidity 5…95 %
  • Packing Units

  • Number of Units in Package 1 1
  • Package 1 Height 14.0 cm
  • Package 1 Length 18.5 cm
  • Package 1 Weight 1.03 kg