TeSys island direct starter, 3 poles, 9A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 9A and motors up to 4kW@400V / 5hp@480V. It provides motor protection functions including thermal overload (setting 0.18-9A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Item specifics

  • Main

  • Average impedance 2.5 mOhm - Ith 15 A 50 Hz
  • Current consumption 160 mA contactor sealed 160 mA contactor closing
  • Device presentation Direct starter connected to an automation controller through a bus coupler Operational only when connected to a bus coupler
  • Device short name TPRST
  • Function available Upstream voltage presence detection Electrical line and load protection Power and energy monitoring when connected with TPRVM voltage module
  • Irms rated making capacity 250 A at 440 V conforming to IEC 60947
  • motor power HP (UL / CSA) 0.33 hp at 120 V AC 60 Hz for 1 phase motors 1 hp at 240 V AC 60 Hz for 1 phase motors 2 hp at 208 V AC 60 Hz for 3 phases motors 2 hp at 240 V AC 60 Hz for 3 phases motors 5 hp at 480 V AC 60 Hz for 3 phases motors 7.5 hp at 600 V AC 60 Hz for 3 phases motors
  • Motor starter type Direct on line
  • Overvoltage category III
  • Poles description 3P (3 NO)
  • Power dissipation per pole 0.2 W AC-3 - Ith 9 A 0.56 W AC-1 - Ith 15 A
  • Product compatibility TPRBC bus coupler TPRVM voltage interface module
  • Product name TeSys island
  • Range TeSys
  • Rated breaking capacity 250 A at 440 V conforming to IEC 60947
  • Reset Remotely or automatically
  • Thermal overload class Class 5…30
  • Thermal protection adjustment range 0.18…9 A
  • Utilisation category AC-1 AC-2 AC-3 AC-4 AC-3e
  • [Icw] rated short-time withstand current 210 A 40 °C - 1 s 105 A 40 °C - 10 s 61 A 40 °C - 1 min 30 A 40 °C - 10 min
  • [Ie] rated operational current 9 A (at <50 °C) at <= 440 V AC-3 15 A (at <50 °C) at <= 440 V AC-1
  • [Ith] conventional free air thermal current 15 A (at 50 °C)
  • [Uc] control circuit voltage 24 V DC supplied by the bus coupler
  • [Ue] rated operational voltage <= 690 V AC 47...63 Hz
  • [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-1
  • [Ui] rated insulation voltage 690 V conforming to IEC 60947-4-1 600 V conforming to UL 60947-4-1 600 V conforming to CSA C22.2 No 60947-4-1
  • Product or component type Motor starter
  • Motor power kW 2.2 kW at 230 V 50 Hz (AC-3) 4 kW at 380...415 V 50 Hz (AC-3) 4 kW at 440 V 50 Hz (AC-3) 5.5 kW at 500 V 50 Hz (AC-3) 5.5 kW at 690 V 50 Hz (AC-3)
  • Power dissipation in W 3.5 W at Ie AC-3
  • Complementary

  • Connections - terminals Screw-clamp terminals 1 cable(s) 1…4 mm² (AWG 16...AWG 12) rigid Screw-clamp terminals 2 cable(s) 1…4 mm² (AWG 16...AWG 12) rigid Screw-clamp terminals 1 cable(s) 1.5…4 mm² (AWG 16...AWG 12) flexible without cable end Screw-clamp terminals 2 cable(s) 1.5…4 mm² (AWG 16...AWG 12) flexible without cable end Screw-clamp terminals 1 cable(s) 1…4 mm² (AWG 16...AWG 12) flexible with cable end Screw-clamp terminals 2 cable(s) 1…2.5 mm² (AWG 16...AWG 14) flexible with cable end
  • Depth 115 mm
  • Electrical durability 2 Mcycles 9 A AC-3 at Ue 440 V 1.2 Mcycles 15 A AC-1 at Ue 440 V
  • Height 116 mm
  • Local signalling 1 LED (green/red) for DS (device status) 1 LED (green/red) for LS (load status)
  • Maximum operating rate 3600 cyc/mn AC-3
  • Mechanical durability 30 Mcycles
  • Monitoring type Time device ON Time device switch ON Number of faults Number of switching cycles Number of device power cycles Average current Iavg Average voltage Vavg Max current Imax Max voltage Vmax Active and reactive power with voltage module Active and reactive energy with voltage module True power factor with voltage module
  • mounting mode Horizontal and vertical (35 mm symmetrical DIN rail)
  • Net weight 0.656 kg
  • Operating time < 100 ms closing < 30 ms opening
  • Product Certifications EAC CSA CCC UL
  • Protection type Thermal overload protection Motor overheat Overcurrent Undercurrent Jam Long start Stall Rapid cycle lockout Phase sequence Rapid restart lockout Phase reversal Phase loss Phase unbalance Ground current
  • Safety performance level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
  • Standards EN/IEC 60947-1 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1
  • Tightening torque 1.7 N.m - with screwdriver flat Ø 6 mm 1.7 N.m - with screwdriver Philips No 2
  • Width 45 mm
  • Environment

  • Ambient air temperature for operation -10…50 °C without derating 50…60 °C with current derating
  • Ambient air temperature for storage -25…70 °C
  • Electromagnetic compatibility Electrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF field immunity test, level 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transient immunity test, level 4, 4 kV, conforming to EN/IEC 61000-4-4 Surge immunity test (differential mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5 Surge immunity test (common mode), level 4, 4 kV, conforming to EN/IEC 61000-4-5 Conducted RF disturbance immunity test, 20 V, conforming to EN/IEC 61000-4-6
  • Fire resistance 960 °C conforming to UL 94 850 °C conforming to IEC 60695-2-1 650 °C conforming to IEC 60695-2-12
  • IP degree of protection IP20
  • Operating altitude 0...2000 m without derating
  • Pollution degree 2
  • protective treatment TC
  • Relative humidity 5…95 %
  • Shock resistance 15 gn (duration = 11 ms) conforming to IEC 60068-2-27
  • Vibration resistance 1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
  • Packing Units

  • Number of Units in Package 1 1
  • Number of Units in Package 2 14
  • Package 1 Height 5.0 cm
  • Package 1 Length 13.0 cm
  • Package 1 Weight 709.0 g
  • Package 1 Width 12.5 cm
  • Package 2 Height 15.0 cm
  • Package 2 Length 40.0 cm
  • Package 2 Weight 10.252 kg
  • Package 2 Width 30.0 cm
  • Unit Type of Package 1 PCE
  • Unit Type of Package 2 S02
  • Contractual warranty

  • Warranty 18 months

Write a review