Miniature circuit-breaker, Acti9 C120N, 1P, 80 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)

Miniature circuit-breaker, Acti9 C120N, 1P, 80 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)

0 reviews 0 sold. Only 1 remain
0.00ريال
Product Code: A9N18357
Availability: In Stock
Viewed 717 times

Product Description

This Acti9 C120N is a low voltage multistandard miniature circuit breaker (MCB). It is a 1P circuit breaker with 1 protected pole, 80A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 3kA at 380VAC to 415VAC conforming to EN/IEC 60947-2 standard and 3kA at 380VAC to 415VAC conforming to EN/IEC 60947-2 standard. It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker protects circuit against short circuit and overload current. The presence of green strip guarantees contact open physically and allows work to be carried out safely on the downstream circuit. It has good overvoltage withstand capacity. The product is designed to offer a high industrial performance level It has an electrical endurance going up to 5000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is going from 380VAC to 415VAC. The Ui rated insulation voltage is 500VAC. Its limitation class 3 (according to EN/IEC60898-1) improves downstream circuit protection cost. The product can be clipped on a DIN rail. Its width is 3 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is white (RAL9003). The dimensions are (W) 27mm x (H) 81mm x (D) 73mm. The weight is 0.205kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 85°C.

Item specifics

  • Main

  • Breaking capacity 3 kA Icu at 380...415 V AC 50/60 Hz IT conforming to EN/IEC 60947-2 20 kA Icu at 130 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12 V DC conforming to EN/IEC 60947-2 15 kA Icu at 125 V DC conforming to EN/IEC 60947-2 10 kA Icu at <= 144 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 A Icn at 230...400 V AC 50/60 Hz conforming to EN/IEC 60898-1
  • Curve code C
  • Device Application Distribution
  • Device short name C120N
  • Network type AC
  • Number of protected poles 1
  • Poles description 1P
  • Product name C120
  • Range Acti9
  • Suitability for isolation Yes conforming to IEC 60947-2
  • Trip unit technology Thermal-magnetic
  • Range of product C120
  • Product or component type Miniature circuit-breaker
  • Complementary

  • 9 mm pitches 3
  • Colour White
  • Comb busbar and distribution block compatibility YES
  • Connections - terminals Tunnel type terminals1…50 mm² rigid Tunnel type terminals1.5…35 mm² flexible
  • Contact position indicator Yes
  • Control type Toggle
  • Depth 73 mm
  • Earth-leakage protection Without
  • Electrical durability 5000 cycles conforming to IEC 60947-2
  • Height 81 mm
  • Limitation class 3 conforming to EN/IEC 60947-2
  • Local signalling ON/OFF indication
  • Locking options description Handle sealable with cable diameter 0.7mm in OFF or ON position
  • Magnetic tripping limit 5...10 x In
  • Mechanical durability 20000 cycles
  • mounting mode Clip-on
  • Mounting support 35 mm symmetrical DIN rail
  • Net weight 0.205 kg
  • network frequency 50/60 Hz
  • Tightening torque 3.5 N.m
  • Width 27 mm
  • Wire stripping length 15 mm
  • [Ics] rated service breaking capacity 15 kA 75 % conforming to EN/IEC 60947-2 - 130 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - 125 V DC 2.25 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - 12 V DC 10 kA 100 % conforming to EN/IEC 60947-2 - <= 144 V DC 7.5 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 12 V AC 50/60 Hz 7500 A 75 % conforming to EN/IEC 60898-1 - 230...400 V AC 50/60 Hz
  • [In] rated current 80 A at 30 °C
  • [Ue] rated operational voltage 380...415 V AC 50/60 Hz 125 V DC <= 144 V DC 12 V DC 220...240 V AC 50/60 Hz 230...400 V AC 50/60 Hz 130 V AC 50/60 Hz 12 V AC 50/60 Hz
  • [Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-2
  • [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN/IEC 60947-2
  • Environment

  • Ambient air temperature for operation -25…70 °C
  • Ambient air temperature for storage -40…85 °C
  • IP degree of protection IP20 conforming to IEC 60529
  • Operating altitude 2000 m
  • Overvoltage category IV
  • Pollution degree 3 conforming to IEC 60947-2
  • Product certifications EAC
  • Relative humidity 95 % at 55 °C
  • Standards EN/IEC 60898-1 EN/IEC 60947-2
  • Tropicalisation 2 conforming to IEC 60068-1
  • Packing Units

  • Number of Units in Package 1 1
  • Number of Units in Package 2 12
  • Number of Units in Package 3 72
  • Package 1 Height 2.7 cm
  • Package 1 Length 8.7 cm
  • Package 1 Weight 193 g
  • Package 1 Width 7.5 cm
  • Package 2 Height 8.5 cm
  • Package 2 Length 32.8 cm
  • Package 2 Weight 2.377 kg
  • Package 2 Width 9.2 cm
  • Package 3 Height 30 cm
  • Package 3 Length 40 cm
  • Package 3 Weight 14.749 kg
  • Package 3 Width 30 cm
  • Unit Type of Package 1 PCE
  • Unit Type of Package 2 BB1
  • Unit Type of Package 3 S03
  • Contractual warranty

  • Warranty 18 months

Write a review

Note: HTML is not translated!
    Bad           Good
Miniature circuit-breaker, Acti9 C120N, 1P, 80 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)

Miniature circuit-breaker, Acti9 C120N, 1P, 80 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)

0.00ريال