multifunction control relay RM17-TE - range 183..528 V AC
- Training
- Industrial Automation and Control
-
Low voltage protection devices
-
Motor protection devices
- Contactors & Reversing Contactors - EasyPact TVS
- Contactors & Reversing Contactors - TeSys D
- Contactors & Reversing Contactors - TeSys D capacitor
- Contactors & Reversing Contactors - TeSys F
- Contactors & Reversing Contactors - TeSys Giga
- Contactors & Reversing Contactors - TeSys K
- Contactors & Reversing Contactors - TeSys LE
- Electronic Over Current Relays - Easy TeSys Protect
- Electronic Overload Relays - EOCR
- Motor management system - TeSys island
- Motor protection circuit breakers - Easy TeSys Power GZ
- Motor protection circuit breakers - TeSys GV2
- Motor protection circuit breakers - TeSys GV3
- Motor protection circuit breakers - TeSys GV4
- Thermal Overload Relays - TeSys Giga
- Thermal Overload Relays - TeSys LR9
- Thermal Overload Relays - TeSys LRD
- Relays and industrial accessories
-
Circuit Breakers and Switches
- Air Circuit Breakers - EasyPact MVS
- Air Circuit Breakers - MasterPact MTZ
- Air Circuit Breakers - MasterPact NW
- Miniature Circuit Breakers - Acti 9 C120
- Miniature Circuit Breakers - Acti 9 iC60
- Miniature Circuit Breakers - Acti 9 iK60
- Miniature Circuit Breakers - Residental Domae
- Miniature Circuit Breakers - Residental Resi9
- Molded Case Circuit Breakers - ComPacT INS
- Molded Case Circuit Breakers - ComPacT NS
- Molded Case Circuit Breakers - ComPacT NSX
- Molded Case Circuit Breakers - Easy CVS
- Molded Case Circuit Breakers - Easy GoPact
- Molded Case Circuit Breakers - Easy GoPact MTS
- Residual current devices - Acti 9 iC60 RCBO
- Residual current devices - Acti 9 iID RCCB
- Residual current devices - Vigi for iC60
- Power Quality and Power Factor Correction
-
Motor protection devices
-
Power supplies & Energy monitoring system
-
Energy meters & supplies
- Advanced metering
- Current Transformers
- EasyLogic DM6000H series VAF PF meters
- EasyLogic PM2000 Power Meters
- Industrial Power supplies - (ABLM / ABLS / ABL8)
- PowerLogic PM3000 Power Meters
- PowerLogic PM5000 Power Meters
- Single phase power supplies - Easy Modicon ABL2
- Temperature controller
- Transformers - Modicon ABT7, ABL6
-
Energy meters & supplies
- Control station & joysticks
- Secure Power
- Enclosures
Your shopping cart is empty!
Product Description
This Harmony RM17-TE relay allows monitoring of power supply circuits in 3-phase networks. This modular multi function 3-phase supply control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slimmest form-factors with 17.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a sealable cover, simple and precise settings with screw trimmers. The product monitors its own power supply, when the power supply is abnormal, the output relay de-energizes. multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC
Item specifics
-
Main
- Contacts type and composition 1 C/O
- Measurement range 208...480 V AC
- Output contacts 1 C/O
- Relay monitored parameters Undervoltage and overvoltage in window mode Asymmetry Phase sequence Phase failure detection
- Relay name RM17TE
- Relay type Multifunction control relay
- time delay Adjustable 0.1...10 s, +/- 10 % of the full scale value Tt- time delay upon fault
- [Uc] control circuit voltage 208...480 V
- Range of product Harmony Control Relays
- Product specific application For 3-phase supply
- Nominal output current 5 A
-
Complementary
- Adjustment of asymmetry threshold 5...15 % of Un selected
- Connections - terminals Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
- Control circuit frequency 50...60 Hz +/- 10 %
- Control circuit voltage limits - 12 % + 10 % Un
- Control type Without test button
- delay at power up 650 ms
- Electrical durability 100000 cycles
- Housing material Self-extinguishing plastic
- Hysteresis 2 %
- Insulation resistance > 500 MOhm at 500 V DC conforming to IEC 60255-5 > 500 MOhm at 500 V DC conforming to IEC 60664-1
- Local signalling LED (green) for power ON LED (yellow) for relay ON
- Maximum measuring cycle 150 ms measurement cycle as true rms value
- Maximum switching current 5 A AC 5 A DC
- Maximum switching voltage 250 V AC 250 V DC
- Measurement error < 0.05 %/°C with temperature variation < 1 % over the whole range with voltage variation
- Measurement voltage limits 183…528 V AC
- Mechanical durability 30000000 cycles
- Minimum switching current 10 mA at 5 V DC
- Mounting support 35 mm symmetrical DIN rail conforming to IEC 60715
- Net weight 0.13 kg
- Operating position Any position without derating
- Operating rate <= 360 operations/hour full load
- Phase failure sensitivity 0.7 Un
- Power consumption in VA 0…22 VA at 400 V AC 50 Hz
- Repeat accuracy 0.5 % for input and measurement circuit 3 % for time delay
- Reset time 1500 ms time delay
- Response time < 200 ms (in the event of a fault)
- Safety reliability data MTTFd = 502.2 years B10d = 470000
- Supply frequency 50/60 Hz +/- 10 %
- Supply voltage limits 183…528 V AC
- Switching capacity in VA 1250 VA
- Threshold adjustment voltage 2...20 % of Un selected -2...-17 % in the range 220 V AC +2...+10 % in the range 480 V AC -2...-12 % in the range 208 V AC
- Tightening torque 0.6…1 N.m conforming to IEC 60947-1
- Utilisation category AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1
- Voltage range 208...480 V phase to phase
- Width 17.5 mm
- [Ui] rated insulation voltage 400 V conforming to IEC 60664-1
- [Un] rated nominal voltage , self-powered
-
Environment
- Ambient air temperature for operation -20…50 °C
- Ambient air temperature for storage -40…70 °C
- Dielectric test voltage 2 kV, 1 min AC 50 Hz conforming to IEC 60255-5 2 kV, 1 min AC 50 Hz conforming to IEC 60664-1
- Directives 89/336/EEC - electromagnetic compatibility 73/23/EEC - low voltage directive
- Electromagnetic compatibility Emission standard for industrial environments conforming to IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 Immunity for industrial environments conforming to IEC 61000-6-2
- IP degree of protection IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529
- marking CE
- Non-dissipating shock wave 4 kV conforming to IEC 60255-5 4 kV conforming to IEC 60664-1 4 kV conforming to IEC 61000-4-5
- Overvoltage category III conforming to IEC 60664-1
- Pollution degree 3 conforming to IEC 60664-1
- Product certifications GOST C-Tick CSA UL GL
- Relative humidity 95 % at 55 °C conforming to IEC 60068-2-30
- Shock resistance 15 gn for 11 ms conforming to IEC 60255-21-1
- Standards IEC 60255-1
- Vibration resistance 0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6 1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1
-
Packing Units
- Number of Units in Package 1 1
- Number of Units in Package 2 48
- Package 1 Height 2.7 cm
- Package 1 Length 9.6 cm
- Package 1 Weight 92.0 g
- Package 1 Width 7.7 cm
- Package 2 Height 15.0 cm
- Package 2 Length 40.0 cm
- Package 2 Weight 4.936 kg
- Package 2 Width 30.0 cm
- Unit Type of Package 1 PCE
- Unit Type of Package 2 S02
-
Contractual warranty
- Warranty 18 months