Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic, Everlink terminals

Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic, Everlink terminals

0 reviews 0 sold. Only 1 remain
0.00ريال
Product Code: GV4P50N
Availability: In Stock
Viewed 756 times

Product Description

TeSys GV motor circuit breaker, 3 poles (3P), 50A/690V, for protection of 3-phase motors 11-22kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by rotary handle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 20-50A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).

Item specifics

  • Main

  • Device Application Motor protection
  • Device short name GV4P
  • Product name TeSys GV4
  • Range TeSys Deca
  • Trip unit technology Electronic Thermal-magnetic
  • Range of product TeSys GV4
  • Product or component type Motor circuit breaker
  • Complementary

  • Breaking capacity code 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947 65 kA at 240 V AC 50/60 Hz conforming to UL 60947 35 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947 8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
  • Colour Grey (RAL 7016)
  • Connections - terminals EverLink BTR screw connectors (top) 1 cable(s) 1.5…70 mm² - solid EverLink BTR screw connectors (top) 1 cable(s) 1.5…50 mm² - flexible EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…95 mm² - solid EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…70 mm² - flexible
  • Control type Rotary handle
  • Depth 165 mm
  • Electrical durability 20000 cycles for AC-3 at 440 V In/2 10000 cycles for AC-3 at 440 V In
  • Height 155 mm
  • Magnetic tripping current 850 A
  • Maximum operating rate 25 cyc/h
  • Mechanical durability 40000 cycles
  • Mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6 Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6 Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
  • Motor power kW 11 kW at 400...415 V AC 50/60 Hz 15 kW at 500 V AC 50/60 Hz 18.5 kW at 660...690 V AC 50/60 Hz 15 kW at 400...415 V AC 50/60 Hz 18.5 kW at 400...415 V AC 50/60 Hz 22 kW at 400...415 V AC 50/60 Hz 18.5 kW at 500 V AC 50/60 Hz 22 kW at 500 V AC 50/60 Hz 30 kW at 500 V AC 50/60 Hz 22 kW at 660...690 V AC 50/60 Hz 30 kW at 660...690 V AC 50/60 Hz 37 kW at 660...690 V AC 50/60 Hz 45 kW at 660...690 V AC 50/60 Hz
  • Net weight 1.6 kg
  • Operating position Any position
  • Phase failure sensitivity Yes conforming to IEC 60947-4-1
  • Poles description 3P
  • Power dissipation per pole 4.6 W
  • Rated duty Continuous conforming to IEC 60947-4-1
  • Suitability for isolation Yes conforming to IEC 60947-1
  • Tightening torque 9 N.m for cable 16…95 mm² 5 N.m for cable 1.5…10 mm²
  • Utilisation category Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1
  • Width 81 mm
  • [In] rated current 50 A
  • [Ith] conventional free air thermal current 115 A conforming to IEC 60947-4-1
  • [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
  • [Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
  • [Ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
  • Environment

  • Ambient air temperature for operation -25…70 °C
  • Ambient air temperature for storage -50…85 °C
  • Climatic withstand conforming to IACS E10
  • Fire resistance 960 °C conforming to IEC 60695-2-11
  • IK degree of protection IK07 conforming to IEC 62262
  • IP degree of protection IP40 conforming to IEC 60529
  • Operating altitude 5000 m
  • Pollution degree 3
  • Product certifications IEC UL CSA CCC EAC ATEX EU-RO MR
  • Standards CSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2
  • Packing Units

  • Number of Units in Package 1 1
  • Number of Units in Package 2 3
  • Package 1 Height 21.0 cm
  • Package 1 Length 22.0 cm
  • Package 1 Weight 1.84 kg
  • Package 1 Width 10.5 cm
  • Package 2 Height 30.0 cm
  • Package 2 Length 40.0 cm
  • Package 2 Weight 6.0 kg
  • Package 2 Width 30.0 cm
  • Unit Type of Package 1 PCE
  • Unit Type of Package 2 S03
  • Contractual warranty

  • Warranty 18 months