electronic overcurrent relay - 0.5..6 A - 220 V AC

electronic overcurrent relay - 0.5..6 A - 220 V AC

0 reviews 0 sold. Only 1 remain
0.00ريال
Product Code: EOCRSE2-05NS
Availability: In Stock
Viewed 561 times

Product Description

Item specifics

  • Main

  • Analogue output range 4...20 mA
  • Device short name EOCR-3D420
  • Network Frequency 50...60 Hz
  • Network type AC
  • protection ajustment range 0.5…10 A
  • Protection type Overload, In > OC setting Sensitivity to phase loss Sensitivity to phase reverse Locked rotor, In > 3 times OC setting Phase unbalance, 50 %
  • Tripping threshold 0.5...6 A
  • Range of product EOCR
  • Product or component type Protection relay
  • Product specific application Overcurrent protection
  • Complementary

  • Connections - terminals Control circuit: cable 2 x 1…1.5 mm²flexible with cable end - M3 Control circuit: cable 2 x 1…1.5 mm²flexible without cable end - M3 Control circuit: cable 1 x 1…2.5 mm²flexible with cable end - M3 Control circuit: cable 1 x 1…2.5 mm²flexible without cable end - M3
  • Contacts type and composition 1 NO + 1 NC (OL)
  • Depth 68 mm
  • Display type 7 segments LED
  • Height 71 mm
  • Mounting support 35 mm DIN rail Panel
  • Net weight 0.325 kg
  • power consumption per relay 3 W
  • Reset Manual reset Electrical 0…1 s by interruption of power supply
  • Short-circuit and overload protection By 4 A gG fuse
  • Tightening torque Control circuit: 0.8...1.2 N.m on cable, 4.7 mm
  • Time delay type O-Time: 0.3, 1...30 s, off (definite) D-Time: 1...120 s, off (definite) O-Time: 1...30 class (inverse) D-Time: 0...120 s (inverse)
  • Width 70 mm
  • [Ue] rated operational voltage 600 V AC 50...60 Hz for power circuit conforming to UL 690 V AC 50...60 Hz for power circuit conforming to CSA 690 V AC 50...60 Hz for power circuit conforming to IEC 60947-4-1
  • [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-4-1
  • [Us] rated supply voltage 220 V AC
  • Environment

  • Ambient air temperature for operation -20…60 °C conforming to IEC 60947-4-1
  • Ambient air temperature for storage -30…80 °C
  • Dielectric strength 2 kV 50...60 Hz in between case and circuit conforming to IEC 60255-5 1 kV 50...60 Hz in between contact conforming to IEC 60255-5 2 kV 50...60 Hz in between circuit conforming to IEC 60255-5
  • Electromagnetic compatibility Resistance to radiated electromagnetic fields: 10 V/m level 3 conforming to IEC 61000-4-3 Resistance to electrostatic discharge: 8 kV air, 6 kV contact conforming to IEC 61000-4-2 Resistance to fast transient: 2 kV conforming to IEC 61000-4-4 Conducted RF disturbances: 10 V conforming to EN 61000-4-6 Conducted RF disturbances: class A conforming to EN 55011
  • Fire resistance 650 °C conforming to IEC 60695-2-12 960 °C conforming to UL 94
  • IP degree of protection IP20 conforming to IEC 60529
  • Operating altitude 2000 m
  • Permissible current 250 V, 5 A AC
  • Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-7
  • Standards IEC 60947-4-1
  • Surge withstand 6 kV conforming to IEC 61000-4-5
  • Vibration resistance 4 gn on panel mounting conforming to IEC 60068-2-6 2 gn on 35 mm DIN rail conforming to IEC 60068-2-6
  • [Ith] conventional free air thermal current 5 A for control circuit
  • Packing Units

  • Number of Units in Package 1 1
  • Number of Units in Package 2 56
  • Number of Units in Package 3 896
  • Package 1 Height 9.5 cm
  • Package 1 Length 5.7 cm
  • Package 1 Weight 221.6 g
  • Package 1 Width 6.3 cm
  • Package 2 Height 30 cm
  • Package 2 Length 40 cm
  • Package 2 Weight 10.38 kg
  • Package 2 Width 30 cm
  • Package 3 Height 75 cm
  • Package 3 Length 120 cm
  • Package 3 Weight 176 kg
  • Package 3 Width 80 cm
  • Unit Type of Package 1 PCE
  • Unit Type of Package 2 S03
  • Unit Type of Package 3 P12

Write a review