iC60N - earth leakage circuit breaker - 1P + N - C curve - 16 A - 30 mA - 240 V
- Training
- Industrial Automation and Control
-
Low voltage protection devices
-
Motor protection devices
- Contactors & Reversing Contactors - EasyPact TVS
- Contactors & Reversing Contactors - TeSys D
- Contactors & Reversing Contactors - TeSys D capacitor
- Contactors & Reversing Contactors - TeSys F
- Contactors & Reversing Contactors - TeSys Giga
- Contactors & Reversing Contactors - TeSys K
- Contactors & Reversing Contactors - TeSys LE
- Electronic Over Current Relays - Easy TeSys Protect
- Electronic Overload Relays - EOCR
- Motor management system - TeSys island
- Motor protection circuit breakers - Easy TeSys Power GZ
- Motor protection circuit breakers - TeSys GV2
- Motor protection circuit breakers - TeSys GV3
- Motor protection circuit breakers - TeSys GV4
- Thermal Overload Relays - TeSys Giga
- Thermal Overload Relays - TeSys LR9
- Thermal Overload Relays - TeSys LRD
- Relays and industrial accessories
-
Circuit Breakers and Switches
- Air Circuit Breakers - EasyPact MVS
- Air Circuit Breakers - MasterPact MTZ
- Air Circuit Breakers - MasterPact NW
- Miniature Circuit Breakers - Acti 9 C120
- Miniature Circuit Breakers - Acti 9 iC60
- Miniature Circuit Breakers - Acti 9 iK60
- Miniature Circuit Breakers - Residental Domae
- Miniature Circuit Breakers - Residental Resi9
- Molded Case Circuit Breakers - ComPacT INS
- Molded Case Circuit Breakers - ComPacT NS
- Molded Case Circuit Breakers - ComPacT NSX
- Molded Case Circuit Breakers - Easy CVS
- Molded Case Circuit Breakers - Easy GoPact
- Molded Case Circuit Breakers - Easy GoPact MTS
- Residual current devices - Acti 9 iC60 RCBO
- Residual current devices - Acti 9 iID RCCB
- Residual current devices - Vigi for iC60
- Power Quality and Power Factor Correction
-
Motor protection devices
-
Power supplies & Energy monitoring system
-
Energy meters & supplies
- Advanced metering
- Current Transformers
- EasyLogic DM6000H series VAF PF meters
- EasyLogic PM2000 Power Meters
- Industrial Power supplies - (ABLM / ABLS / ABL8)
- PowerLogic PM3000 Power Meters
- PowerLogic PM5000 Power Meters
- Single phase power supplies - Easy Modicon ABL2
- Temperature controller
- Transformers - Modicon ABT7, ABL6
-
Energy meters & supplies
- Control station & joysticks
- Secure Power
- Enclosures
Your shopping cart is empty!
Product Description
This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+N circuit breaker with 1 protected pole, 16A In rated current and C tripping curve. The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 6000A according 0 standard. Its unique Visitrip indicator reduces intervention time by showing the faulty circuit. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. This product is compliant with IEC 61009-2-2 and IEC 61009-1 standards. It has an electrical endurance going up to 5000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 2. The product color is white (RAL9003). The dimensions are (W) 18mm x (H) 110mm x (D) 77.5mm. The weight is 205g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -15°C to 60°C. The storage temperature is from -40°C to 85°C.
Item specifics
-
Main
- Breaking capacity 6000 A Icn at 230/240 V AC 50/60 Hz
- Circuit breaker application Distribution
- Curve code C
- Device short name iC60N RCBO
- Earth-leakage sensitivity 30 mA
- Earthing system TN
- Neutral position Left
- Number of protected poles 1
- Poles description 1P + Ns
- Product name Acti9 iC60 RCBO
- Range Acti9
- [In] rated current 16 A at 50 °C
- Product or component type Residual current breaker with overcurrent protection (RCBO)
-
Complementary
- 9 mm pitches 2
- Colour White
- Comb busbar and distribution block compatibility NO
- Connections - terminals Screw clamp terminal (top) 1…25 mm² rigid without cable end Screw clamp terminal (top) 1…16 mm² flexible Screw clamp terminal (bottom) 1…16 mm² rigid without cable end Screw clamp terminal (bottom) 1…10 mm² flexible
- Contact position indicator Yes
- Control type Toggle
- Depth 77.5 mm
- Device location in system Outgoer
- Earth-leakage protection Integrated
- Earth-leakage protection class Type A
- Earth-leakage protection time delay Instantaneous
- Electrical durability 5000 cycles
- Height 110 mm
- Limitation class 3
- Local signalling ON/OFF indication
- Locking options description ON/OFF locking facilities
- Mechanical durability 20000 cycles
- mounting mode Clip-on
- Mounting support DIN rail
- network frequency 50 Hz
- Network type AC
- Product Weight 205 g
- Provision for padlocking Padlockable with padlock Ø 4 mm
- Residual current tripping technology Voltage dependent
- Suitability for isolation Yes
- Surge current 250 A
- Tightening torque Power circuit: 3.5 N.m top Power circuit: 2 N.m bottom
- Trip unit technology Thermal-magnetic
- Width 18 mm
- Wire stripping length Power circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection
- [Ics] rated service breaking capacity 6000 A at 230/240 V AC 50/60 Hz
- [Icw] rated short-time withstand current Icw: 250 A during 8/20 µs impulse withstand
- [Ue] rated operational voltage 230/240 V AC 50/60 Hz
- [Uimp] rated impulse withstand voltage 4 kV