EASYLOGIC DM6200H VAF PF DPM NONC CL1.0
0.00ريال
Product Code: METSEDM6000HCL10NC
Availability: In Stock
Viewed 551 times
Categories
Cart
Account
Search
Recent View
Go to Top
All Categories
×
- Training
- Industrial Automation and Control
-
Low voltage protection devices
-
Motor protection devices
- Contactors & Reversing Contactors - EasyPact TVS
- Contactors & Reversing Contactors - TeSys D
- Contactors & Reversing Contactors - TeSys D capacitor
- Contactors & Reversing Contactors - TeSys F
- Contactors & Reversing Contactors - TeSys Giga
- Contactors & Reversing Contactors - TeSys K
- Contactors & Reversing Contactors - TeSys LE
- Electronic Over Current Relays - Easy TeSys Protect
- Electronic Overload Relays - EOCR
- Motor management system - TeSys island
- Motor protection circuit breakers - Easy TeSys Power GZ
- Motor protection circuit breakers - TeSys GV2
- Motor protection circuit breakers - TeSys GV3
- Motor protection circuit breakers - TeSys GV4
- Thermal Overload Relays - TeSys Giga
- Thermal Overload Relays - TeSys LR9
- Thermal Overload Relays - TeSys LRD
- Relays and industrial accessories
-
Circuit Breakers and Switches
- Air Circuit Breakers - EasyPact MVS
- Air Circuit Breakers - MasterPact MTZ
- Air Circuit Breakers - MasterPact NW
- Miniature Circuit Breakers - Acti 9 C120
- Miniature Circuit Breakers - Acti 9 iC60
- Miniature Circuit Breakers - Acti 9 iK60
- Miniature Circuit Breakers - Residental Domae
- Miniature Circuit Breakers - Residental Resi9
- Molded Case Circuit Breakers - ComPacT INS
- Molded Case Circuit Breakers - ComPacT NS
- Molded Case Circuit Breakers - ComPacT NSX
- Molded Case Circuit Breakers - Easy CVS
- Molded Case Circuit Breakers - Easy GoPact
- Molded Case Circuit Breakers - Easy GoPact MTS
- Residual current devices - Acti 9 iC60 RCBO
- Residual current devices - Acti 9 iID RCCB
- Residual current devices - Vigi for iC60
- Power Quality and Power Factor Correction
-
Motor protection devices
-
Power supplies & Energy monitoring system
-
Energy meters & supplies
- Advanced metering
- Current Transformers
- EasyLogic DM6000H series VAF PF meters
- EasyLogic PM2000 Power Meters
- Industrial Power supplies - (ABLM / ABLS / ABL8)
- PowerLogic PM3000 Power Meters
- PowerLogic PM5000 Power Meters
- Single phase power supplies - Easy Modicon ABL2
- Temperature controller
- Transformers - Modicon ABT7, ABL6
-
Energy meters & supplies
- Control station & joysticks
- Secure Power
- Enclosures
Shopping Cart
×
Your shopping cart is empty!
Search
×
Recent View Products
×
Product Description
This digital panel meter is part of the EasyLogic Digital Panel Meter Series. The device is able to analyse the load and indicate current burden with a tricolor bar. Providing Class 1 active energy accuracy per IEC 62053-21 standard, the meter will measure voltage, current and power factor. The meter has a 4 digits, eight segments, 15 mm height and bright red LED display. Mechanical dimensions are 96 mm in width, 96 mm in height and 80 mm in depth, for a product weight of 400 g.
Item specifics
-
Main
- Device short name DM6000H
- Product name EasyLogic DM6X00H NC
- Range EasyLogic
- Product or component type VAF PF meter
-
Complementary
- Accuracy class Class 1
- Communication of data Reading of measurements Instantaneous and demand values Revolution speed All counters
- Communication port protocol -
- Connections - terminals Current circuit: screw clamp terminals (bottom) 2.08…3.31 mm² cable(s) Voltage circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s) Control circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s)
- Counter functions Power interruption ON hour counting
- Demand intervals 1 s
- Depth Outside : 13 mm Panel : 49 mm
- Device application Remote monitoring
- Display colour Red
- Display digits 12 digit(s) - 14.2 mm in height
- Display type 8 segments LED
- Electrical insulation class Class II
- Flame retardance V-0 conforming to UL 94
- Frequency measurement range 45…65 Hz
- Height 96 mm
- Installation category III
- Local signalling Green LED: activity Red LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
- Material Polycarbonate
- Maximum power consumption in VA 4 VA at 240 V between phase and neutral
- Maximum power consumption in W 2 W at 240 V
- Measurement accuracy Frequency +/- 0.05 % Power factor +/- 0.01 Current +/- 1 % Voltage +/- 1 %
- Measurement category Category III 480 V
- Measurement current 5…6000 mA
- Measurement voltage 35…480 V AC 50...60 Hz between phases 46…277 V AC 50...60 Hz between phase and neutral 277…999000 V AC 50...60 Hz with external VT
- Messages display capacity 3 fields of 4 characters
- Metering type Unbalance current Calculated neutral current Unbalance voltage Rotation speed Phase currents Voltage U21, U32, U13, V1, V2, V3 Frequency Average voltage Vavg Average current Iavg
- mounting mode Flush-mounted
- Mounting support Framework
- Net weight 300 g
- network frequency 50 Hz 60 Hz
- Product Certifications CE conforming to IEC 61010-1 CULus conforming to UL 61010-1 CULus conforming to CSA C22.2 No 61010-1 C-Tick
- Sampling rate 32 samples/cycle
- Signal Current 0.005...10 A (impedance 0.3 MOhm)6 x
- Standards IEC 61010-1:ed. 3 UL 61010-1:ed. 3
- Tamperproof of settings Protected by access code
- Tightening torque Current circuit: 0.9…1 N.m Philips No 2 screwdriver Voltage circuit: 0.9…1 N.m Philips No 2 screwdriver Control circuit: 0.9…1 N.m Philips No 2 screwdriver
- Type of installation Indoor installation
- Type of measurement Current Voltage Frequency RPM
- type of network 2P + N 2P 3P + N 3P 1P + N
- Width 96 mm
- Wire stripping length Current circuit: 3.68 mm Voltage circuit: 7 mm Control circuit: 7 mm
- [In] rated current 1 A 5 A
- [Us] rated supply voltage 48...277 V AC 45...65 Hz 48...277 V DC
-
Environment
- Ambient air temperature for operation -10…60 °C
- Ambient air temperature for storage -20…70 °C
- Electromagnetic compatibility Electrostatic discharge conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 Surge immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Magnetic field at power frequency conforming to IEC 61000-4-8 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 Emission tests conforming to FCC part 15 class A Emission tests conforming to FCC part 15 Subpart C Emission tests conforming to FCC part 15 Subpart E
- IP degree of protection IP51 front: conforming to IEC 60529 IP30 body: conforming to IEC 60529
- Operating altitude <= 2000 m
- Overvoltage category III
- Pollution degree 2
- Relative humidity 5…95 % at 50 °C
- Service life 7 year(s)
-
Packing Units
- Number of Units in Package 1 1
- Number of Units in Package 2 18
- Number of Units in Package 3 144
- Package 1 Height 8.700 cm
- Package 1 Length 12.000 cm
- Package 1 Weight 340.000 g
- Package 1 Width 12.000 cm
- Package 2 Height 30.000 cm
- Package 2 Length 40.000 cm
- Package 2 Weight 6.739 kg
- Package 2 Width 30.000 cm
- Package 3 Height 75.000 cm
- Package 3 Length 80.000 cm
- Package 3 Weight 60.960 kg
- Package 3 Width 60.000 cm
- Unit Type of Package 1 PCE
- Unit Type of Package 2 S03
- Unit Type of Package 3 P06