Controller M100 - 9I/7O relay - 220VAC
- Training
- Industrial Automation and Control
-
Low voltage protection devices
-
Motor protection devices
- Contactors & Reversing Contactors - EasyPact TVS
- Contactors & Reversing Contactors - TeSys D
- Contactors & Reversing Contactors - TeSys D capacitor
- Contactors & Reversing Contactors - TeSys F
- Contactors & Reversing Contactors - TeSys Giga
- Contactors & Reversing Contactors - TeSys K
- Contactors & Reversing Contactors - TeSys LE
- Electronic Over Current Relays - Easy TeSys Protect
- Electronic Overload Relays - EOCR
- Motor management system - TeSys island
- Motor protection circuit breakers - Easy TeSys Power GZ
- Motor protection circuit breakers - TeSys GV2
- Motor protection circuit breakers - TeSys GV3
- Motor protection circuit breakers - TeSys GV4
- Thermal Overload Relays - TeSys Giga
- Thermal Overload Relays - TeSys LR9
- Thermal Overload Relays - TeSys LRD
- Relays and industrial accessories
-
Circuit Breakers and Switches
- Air Circuit Breakers - EasyPact MVS
- Air Circuit Breakers - MasterPact MTZ
- Air Circuit Breakers - MasterPact NW
- Miniature Circuit Breakers - Acti 9 C120
- Miniature Circuit Breakers - Acti 9 iC60
- Miniature Circuit Breakers - Acti 9 iK60
- Miniature Circuit Breakers - Residental Domae
- Miniature Circuit Breakers - Residental Resi9
- Molded Case Circuit Breakers - ComPacT INS
- Molded Case Circuit Breakers - ComPacT NS
- Molded Case Circuit Breakers - ComPacT NSX
- Molded Case Circuit Breakers - Easy CVS
- Molded Case Circuit Breakers - Easy GoPact
- Molded Case Circuit Breakers - Easy GoPact MTS
- Residual current devices - Acti 9 iC60 RCBO
- Residual current devices - Acti 9 iID RCCB
- Residual current devices - Vigi for iC60
- Power Quality and Power Factor Correction
-
Motor protection devices
-
Power supplies & Energy monitoring system
-
Energy meters & supplies
- Advanced metering
- Current Transformers
- EasyLogic DM6000H series VAF PF meters
- EasyLogic PM2000 Power Meters
- Industrial Power supplies - (ABLM / ABLS / ABL8)
- PowerLogic PM3000 Power Meters
- PowerLogic PM5000 Power Meters
- Single phase power supplies - Easy Modicon ABL2
- Temperature controller
- Transformers - Modicon ABT7, ABL6
-
Energy meters & supplies
- Control station & joysticks
- Secure Power
- Enclosures
Your shopping cart is empty!
Product Description
This product is part of the Easy modicon M100 range, an offer of logic controllers for simple machines up to 40 I/O. This logic controller provides 4 fast inputs, 2 high speed inputs, 3 regular inputs and 7 normally opened relay outputs. It is an Easy Modicon logic controller with an input voltage of 24V DC, an output voltage of 24V DC, 220V AC and an output current of 2A. Easy to maintain and update with its micro SD memory card. Integrated connections are USB port with mini B USB 2.0 connector, non isolated serial link 1 and RS485 interface and non isolated serial link 2 and RS232/RS485 interface. It is a controller with an internal flash of 512KB and a micro SD card capacity of 32GB. It is an IP20 rated product. Its dimensions are 110mm (Width) x 70mm (Depth) x 90mm (Height). It weighs 0.295kg. Designed for automation of small finishing, production, assembly or packaging machines. This product is certified by CE. It meets EN/IEC 61010-2-201 and EN/IEC 61131-2 standards. It supports DIN rail mount. Entry-level plc perfectly suited to meet specific needs of emerging markets at an affordable price without compromise. Cost-effective and easy solution to sequential control needs for your simple machines up to 40 I/O.
Item specifics
-
Main
- Discrete I/O number 16
- Discrete input current 7 mA for regular input 7 mA for fast input 9 mA for high speed input
- Discrete input number I2...I5: 4 fast input I6...I8: 3 regular input I0...I1: 2 high speed input
- Discrete input voltage 24 V
- Discrete input voltage type DC
- Discrete output current 2 A
- Discrete output number 7 relay
- Discrete output type Relay normally open
- Discrete output voltage 24 V DC 220 V AC
- Power consumption in VA 30…40 VA at 100...240 V AC (with max I/O)
- Range of product Easy Modicon M100
- Product or component type Logic controller
- [Us] rated supply voltage 100...240 V AC
-
Complementary
- Communication port protocol USB port: USB - SoMachine-Network Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network
- Configurable filtering time 0 ms for input 3 ms for input 12 ms for input
- Control signal type Quadrature (x1, x2, x4) at 60 kHz for fast input (HSC mode) Pulse/direction at 60 kHz for fast input (HSC mode) Single phase at 60 kHz for fast input (HSC mode) CW/CCW at 60 kHz for fast input (HSC mode)
- Counting input number 2 fast input (HSC mode) at 60 kHz 32 bits
- Data storage equipment 32 GB micro SD card (optional)
- Depth 70 mm
- Electrical connection removable screw terminal blockfor inputs removable screw terminal blockfor outputs removable screw terminal block, 4 terminal(s) for connecting the serial link1 Mini B USB 2.0 connectorfor a programming terminal removable screw terminal block, 3 terminal(s) for connecting the 100-240 V AC power supply
- Electrical durability 100000 cycles AC-12, 240 V, 480 VA, resistive 100000 cycles DC-12, 24 V, 48 W, resistive
- Exct time for event task 60 µs response time
- Execution time for 1 KInstruction 0.3 ms for event and periodic task
- Execution time per instruction 0.2 µs Boolean
- Height 90 mm
- Input impedance 3.3 kOhm for regular input 3.3 kOhm for fast input 2.81 kOhm for high speed input
- Inrush current 50 A
- Insulation Between input and internal logic at 560 V AC Between fast input and internal logic at 560 V AC Between input groups at 560 V AC Non-insulated between inputs Between output and internal logic at 1780 V AC Between output groups at 1780 V AC Between supply and internal logic at 1780 V AC
- Integrated connection type USB port with mini B USB 2.0 connector Non isolated serial link serial 1 with terminal block connector and RS485 interface Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface
- Local signalling 1 LED (green) for PWR 1 LED (green) for RUN 1 LED (red) for module error (ERR) 1 LED (green) for SD card access (SD) 1 LED (green) for SL1 1 LED per channel (green) for I/O state
- Maximum cable distance between devices Shielded cable: <10 m for fast input Shielded cable: <10 m for high speed input Unshielded cable: <150 m for output Unshielded cable: <50 m for regular input
- Maximum current per output common 4 A at COM 0 4 A at COM 1
- Mechanical durability 20000000 cycles for relay output
- Memory capacity 1024 kB internal flash with 10000 instructions for backup of programs
- Minimum load 10 mA at 5 V DC for relay output
- Mounting support Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715
- Net weight 0.31 kg
- network frequency 50/60 Hz
- Output voltage limits 30 V DC 250 V AC
- Regulation loop Adjustable PID regulator up to 14 simultaneous loops
- Response time 10 ms turn-on, Q0...Q6 terminal(s) for relay output 10 ms turn-off, Q0...Q6 terminal(s) for relay output 35 µs turn-on, I2...I5 terminal(s) for fast input 100 µs turn-off, I2...I5 terminal(s) for fast input 5 µs turn-on, I0...I1 terminal(s) for high speed input 5 µs turn-off, I0...I1 terminal(s) for high speed input 35 µs turn-on, I6...I8 terminal(s) for regular input 100 µs turn-off, I6...I8 terminal(s) for regular input
- Sensor power supply 24 V DC
- Supply voltage limits 85…264 V
- Switching frequency 0.1 Hz with maximum load 5 Hz without maximum load
- Transmission rate 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 12 Mbit/s for USB
- Voltage state 0 guaranteed <= 5 V for input
- Voltage state 1 guaranteed >= 15 V for input
- Width 110 mm
-
Environment
- Ambient air temperature for operation 0…55 °C (horizontal installation)
- Ambient air temperature for storage -25…70 °C
- Electromagnetic compatibility Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2 Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2 Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz...3 GHz) conforming to EN/IEC 61000-4-3 Conducted emission - test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011 Conducted emission - test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011 Radiated emission - test level: 40 dBμV/m QP class A (10 m) conforming to EN/IEC 55011 Radiated emission - test level: 47 dBμV/m QP class A (10 m) conforming to EN/IEC 55011 Magnetic field at power frequency - test level: 30 A/m (I/O) conforming to EN/IEC 61000-4-8 Electrical fast transient/burst immunity test - test level: 2 kV (power lines) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 2 kV (relay output) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 1 kV (I/O) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 1 kV (serial link) conforming to EN/IEC 61000-4-4 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 2 kV (power lines (AC)) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 2 kV (relay output) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV (I/O) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV (shielded cable) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 0.5 kV class A (power lines (DC)) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV class A (power lines (AC)) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV (relay output) conforming to EN/IEC 61000-4-5 Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
- Immunity to microbreaks 10 ms
- IP degree of protection IP20 with protective cover in place
- Operating altitude 0...2000 m
- Pollution degree <= 2
- Product certifications CE
- Relative humidity 10…95 %, without condensation (in operation) 10…95 %, without condensation (in storage)
- Shock resistance 15 gn for 11 ms 30 gn for 6 ms
- Standards EN/IEC 61010-2-201 EN/IEC 61131-2
- Storage altitude 0…3000 m
- Vibration resistance 3.5 mm at 5…8.4 Hz on symmetrical rail 1 gn at 8.4…150 Hz on symmetrical rail 3.5 mm at 5…8.4 Hz on panel mounting 3 gn at 8.4…150 Hz on panel mounting
-
Packing Units
- Number of Units in Package 1 1
- Number of Units in Package 2 18
- Number of Units in Package 3 432
- Package 1 Height 9.493 cm
- Package 1 Length 13.668 cm
- Package 1 Weight 450 g
- Package 1 Width 12.157 cm
- Package 2 Height 30 cm
- Package 2 Length 40 cm
- Package 2 Weight 8600 g
- Package 2 Width 30 cm
- Package 3 Height 95 cm
- Package 3 Length 120 cm
- Package 3 Weight 215400 g
- Package 3 Width 80 cm
- Unit Type of Package 1 PCE
- Unit Type of Package 2 S03
- Unit Type of Package 3 P12