VarPlus logic is a simple and efficient Power Controller for a automatic power factor correction equipment to maintain the power factor. It is a simple and intelligent relay which measures,monitor and Controls the reactive energy. It comes with Easy Commisioning , Step Size detection and monitoring along with the variour alarms. VPL12 can be used for 12 steps in a PFC equippment.

Item specifics

  • Main

  • Device short name VPL12
  • Product name PowerLogic PFC Controller
  • Range PowerLogic
  • Product or component type Power factor controller
  • Complementary

  • Colour code Front: dark grey RAL 7016
  • cut-out dimensions 138 x 138 mm
  • Data recording 5 alarms
  • Depth 58 mm
  • Device connection Communication protocol: Modbus interface: RS485
  • Display size 56 x 25 mm
  • Display type Backlit LCD
  • Function Available Manual programming Automatic initialisation Automatic detection Advanced programming (expert) Any step sequence
  • Height 144 mm
  • Information displayed Number of switching cycles per step Individual step size in kVAr Remaining step capacity in %
  • Input function Switch: 1 x dry contact
  • Input type Phase to phase Phase to neutral Insensitive to CT polarity Insensitive to phase rotation polarity Current input CT...X/5 A and X/1 A
  • Maximum at the common terminal 10 A
  • Measurement accuracy Voltage +/- 1 % Current +/- 1 % Frequency +/- 1 % Energy (P,Q,S) +/- 2 % Cos φ +/- 2 % Total voltage harmonic distortion THD (U) +/- 2 % Individual voltage harmonic +/- 3 % Temperature +/- 3 °C
  • Measurement current 0…5 A
  • Measurement voltage limits 90…550 V AC 50/60 Hz
  • Metering type Power factor and displacement PF (signed, four quadrant) Total current harmonic distortion THD (I) Power factor average over lifetime Temperature maximum Phase current I1, I2, I3 RMS on load Active power P, P1, P2, P3 on load Reactive power Q, Q1, Q2, Q3 on load Apparent power S, S1, S2, S3 on load Voltage U21, U32, U13, V1, V2, V3 on load
  • Mounting location In cabinet
  • mounting mode Flush-mounted
  • Mounting support Panel - thickness: 1…3 mm
  • Net weight 0.6 kg
  • Number of quadrant operation for generator application 4
  • Number of step output contacts 12
  • Operating mode Manual or automatic
  • Operational counter alarm 65000 cycles without maintenance
  • Operational Hours alarm 100000 h without maintenance
  • Output type Control relay: 0.2 A 110 V DC Control relay: 1 A 48 V DC Control relay: 2 A 400 V AC 50/60 Hz Control relay: 1 A 24 V DC Control relay: 5 A 250 V AC 50/60 Hz Control relay: 5 A 120 V AC 50/60 Hz Fan: 5 A 250 V AC 50/60 Hz Fan: 1 A 48 V DC Alarm relay: 5 A 250 V AC 50/60 Hz Alarm relay: 1 A 48 V DC
  • Provided equipment User manual
  • Settings operating mode Automatic Manual
  • Time delay range 1...6500 s (on reconnection) 1...6500 s (on response)
  • Type of alarms Step power loss (< 75 %) / Action: message and alarm contact + step blocked Step faulty / Action: message and alarm contact + step blocked High current (> 6 A CT) / Action: message and alarm contact Hunting (unstable regulation) / Action: message and alarm contact + step blocked Low current (< 15 mA CT) / Action: message and alarm contact Overcompensation / Action: message and alarm contact Capacitor current overload (Irms/I1) (> 130 % I1) / Action: message and alarm contact + step switched off Overtemperature (50 °C) / Action: message and alarm contact + step switched off Overtemperature (30 °C) / Action: fan switch Overvoltage (+/- 10 %) / Action: message and alarm contact + control stopped Total harmonic distortion (> 7 %) / Action: message and alarm contact + step switched off
  • Type of measurement Capacitor current overload Irms/I1 Individual voltage harmonic Power factor Operating time Cos φ Ambient temperature inside the cubicle Tan φ
  • Type of setting Choice of stepping programs: auto Choice of stepping programs: LIFO Choice of stepping programs: linear Delay between 2 successive switch on the same step: 5...1200 s Step configuration programming: auto Step configuration programming: off Step configuration programming: fixed Target cos phi: 0.7 inductive...0.7 capacitive Target cos phi: dual cos φ
  • Width 144 mm
  • [Us] rated supply voltage 90...550 V AC <= 999 kV AC with external VT
  • Environment

  • Ambient air temperature for operation -20…60 °C
  • Ambient air temperature for storage -40…85 °C
  • IP degree of protection Front face: IP41 Rear face: IP20
  • Operating altitude <= 2000 m
  • Product certifications EAC NRTL cNRTL CE
  • Standards IEC 61000-6-4 UL 61010-1 EN 61010-1 IEC 61000-6-2 IEC 61326-1
  • Packing Units

  • Number of Units in Package 1 1
  • Number of Units in Package 2 8
  • Number of Units in Package 3 64
  • Package 1 Height 9.200 cm
  • Package 1 Length 18.400 cm
  • Package 1 Weight 724.000 g
  • Package 1 Width 17.700 cm
  • Package 2 Height 30.000 cm
  • Package 2 Length 40.000 cm
  • Package 2 Weight 6.155 kg
  • Package 2 Width 30.000 cm
  • Package 3 Height 75.000 cm
  • Package 3 Length 80.000 cm
  • Package 3 Weight 58.408 kg
  • Package 3 Width 60.000 cm
  • Unit Type of Package 1 PCE
  • Unit Type of Package 2 S03
  • Unit Type of Package 3 P06

Write a review

Note: HTML is not translated!
    Bad           Good
Power Factor controller - VarPlus Logic - VPL 12

Power Factor controller - VarPlus Logic - VPL 12

0.00ريال