PM5100 Meter, without communication, up to 15th H, 1DO 33 alarms

PM5100 Meter, without communication, up to 15th H, 1DO 33 alarms

0 reviews 0 sold. Only 1 remain
0.00ريال
Product Code: METSEPM5100
Availability: In Stock
Viewed 633 times

Product Description

This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 64 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to 15th Harmonic. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 415 VAC and 125 to 250 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 35 to 690 VAC at 47 to 63 Hz. Measurement range between Phase and Neutral is 20 to 400VAC at 47 to 63 Hz. Communication is pulse output only. The meter also has 33 configurable alarms. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 2.83 inches (72 millimetres), height 3.78 inches (96 millimetres) and product weight 13.4 onces (380 g).

Item specifics

  • Main

  • Device short name PM5100
  • Product name PowerLogic PM5000
  • Range PowerLogic
  • Product or component type Power meter
  • Complementary

  • Accuracy class Class 0.5S active energy conforming to IEC 62053-22
  • Analogue input type Voltage (impedance 5 MOhm) Current (impedance <= 0.3 mOhm)
  • Communication port protocol -
  • Communication port support -
  • Connections - terminals Voltage circuit: screw terminal block4 Control circuit: screw terminal block2 Current transformer: screw terminal block6 Input/output circuit: screw terminal block6 RS485 link: screw terminal block4
  • Data recording Min/max of instantaneous values Time stamping
  • Depth 72 mm
  • Device application Power monitoring
  • Display resolution 128 x 128 pixels
  • Display type Monochrome graphic LCD
  • Frequency measurement range 45…65 Hz
  • Height 96 mm
  • Maximum power consumption in VA 11 VA at 415 V
  • Measurement accuracy Active energy +/- 0.5 % Reactive energy +/- 2 % Active power +/- 0.5 % Apparent power +/- 0.5 % Frequency +/- 0.05 % Power factor +/- 0.5 Current +/- 0.5 % Voltage +/- 0.5 % Apparent energy +/- 0.5 % Reactive power +/- 2 %
  • Measurement current 50…8500 mA
  • Measurement voltage limits 35…760 V AC 45...65 Hz between phases 20…400 V AC 45...65 Hz between phase and neutral
  • mounting mode Flush-mounted
  • Mounting support Framework
  • Net weight 380 g
  • network frequency 60 Hz 50 Hz
  • Number of inputs 0
  • Number of outputs 1 pulse (energy)
  • Power quality analysis up to the 15th harmonic
  • Product Certifications CE conforming to IEC 61010-1 CULus conforming to UL 61010-1
  • Ride-through time 80 ms 120 V AC typical 100 ms 230 V AC typical 100 ms 415 V AC typical 50 ms 125 V DC typical
  • Sampling rate 64 samples/cycle
  • Standards EN 50470-1 IEC 62053-22:2020 UL 61010-1 IEC 62053-24 IEC 61557-12:2015 EN 50470-3 IEC 60529 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015
  • Supply voltage limits 90...450 V AC 45...65 Hz 100...300 V DC
  • Type of measurement Current Voltage Frequency Power factor Energy Active and reactive power
  • type of network 3P + N 1P + N 3P
  • Width 96 mm
  • [In] rated current 5 A 1 A
  • Environment

  • Ambient air temperature for operation -25…70 °C meter -20…70 °C display -25…-20 °C (with reduced performance) display
  • Ambient air temperature for storage -40…85 °C
  • Electromagnetic compatibility Limits for harmonic current emissions class A conforming to IEC 61000-3-2 Electrostatic discharge level 4 conforming to IEC 61000-4-2 Conducted RF disturbances level 3 conforming to IEC 61000-4-6 Magnetic field at power frequency level 4 conforming to IEC 61000-4-8 Conducted and radiated emissions class B conforming to EN 55022 Immunity to conducted disturbances - test level: 150 kHz...80 MHz conforming to IEC 61000-4-6 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 Surge immunity test conforming to IEC 61000-4-5 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
  • IP degree of protection IP54 display: conforming to IEC 60529 IP30 rear: conforming to IEC 60529
  • Operating altitude 2000 m CAT III
  • Pollution degree 2
  • Relative humidity 5…95 % at 50 °C non-condensing
  • Packing Units

  • Number of Units in Package 1 1
  • Number of Units in Package 2 12
  • Number of Units in Package 3 96
  • Package 1 Height 12.000 cm
  • Package 1 Length 13.000 cm
  • Package 1 Weight 477.000 g
  • Package 1 Width 13.000 cm
  • Package 2 Height 30.000 cm
  • Package 2 Length 40.000 cm
  • Package 2 Weight 6.331 kg
  • Package 2 Width 30.000 cm
  • Package 3 Height 75.000 cm
  • Package 3 Length 80.000 cm
  • Package 3 Weight 61.436 kg
  • Package 3 Width 60.000 cm
  • Unit Type of Package 1 PCE
  • Unit Type of Package 2 S03
  • Unit Type of Package 3 P06

Write a review