Logic controller, 16 inputs/outputs, 7 relay outputs, 100…240 V AC

Logic controller, 16 inputs/outputs, 7 relay outputs, 100…240 V AC

0 reviews 0 sold. Only 1 remain
0.00ريال
Product Code: TM221C16R
Availability: In Stock
Viewed 1776 times

Product Description

This product is part of the Modicon M221 range, an offer of programmable logic controllers for hardwired architectures. This logic controller provides 9 discrete inputs and 7 relay outputs with 10bit input resolution, normally opened relay output. It is a Modicon logic controller with a rated supply voltage of 100V to 240V AC, an output voltage of 5V to 125V DC, 5V to 250V AC and an output current of 2A with sink or source input logic. This product requires minimal installation and offers tremendous versatility. Integrated connections are USB port with mini B USB 2.0 connector, non isolated serial link serial 1 with RJ45 connector and RS485 interface and non isolated serial link serial 2 with RJ45 connector and RS232/RS485 interface. It is a Modicon M221 controller with a network frequency of 50/60Hz, 256KB for internal variables RAM, user application and data RAM, built-in flash memory of 256KB and SD card memory capacity of 2GB. It is an IP20 rated product. Its dimensions are 95mm (Width) x 70mm (Depth) x 90mm (Height). It weighs 0.346kg. This product is certified by CE, IACS E10, RCM, ABS, LR, DNV-GL, CSA, EAC and CULus. It meets EN/IEC 60664-1, EN/IEC 61131-2 and EN/IEC 61010-2-201 standards. It supports DIN rail mount. Achieve benchmark performance while increasing profitability with the Modicon M221 through intuitive machine programming with SoMachine Basic, ready-to-use applications and function blocks

Item specifics

  • Main

  • Analogue input number 2 at 0...10 V
  • Discrete input number 9, discrete input conforming to IEC 61131-2 Type 1
  • Discrete output current 2 A
  • Discrete output number 7 relay
  • Discrete output type Relay normally open
  • Discrete output voltage 5...125 V DC 5...250 V AC
  • Range of product Modicon M221
  • Product or component type Logic controller
  • [Us] rated supply voltage 100...240 V AC
  • Complementary

  • Absolute accuracy error +/- 1 % of full scale for analog input
  • Analogue input resolution 10 bits
  • Backup time 1 year at 25 °C (by interruption of power supply)
  • Battery type BR2032 or CR2032X lithium non-rechargeable
  • Clock drift <= 30 s/month at 25 °C
  • Communication port protocol USB port: USB - SoMachine-Network Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network
  • Configurable filtering time 0 ms for input 3 ms for input 12 ms for input
  • Conversion time 1 ms per channel + 1 controller cycle time for analogue input analog input
  • counter function Single phase Frequency meter Dual phase (quadrature) Dual phase (pulse/direction)
  • Counting input number 4 fast input (HSC mode) at 100 kHz 32 bits
  • Data backed up 256 kB built-in flash memory for backup of application and data
  • Data storage equipment 2 GB SD card (optional)
  • Depth 70 mm
  • Discrete I/O number 16
  • Discrete input current 7 mA for discrete input 5 mA for fast input
  • Discrete input logic Sink or source (positive/negative)
  • Discrete input voltage 24 V
  • Discrete input voltage type DC
  • Electrical connection removable screw terminal block for inputs removable screw terminal block for outputs terminal block, 3 terminal(s) for connecting the 24 V DC power supply connector, 4 terminal(s) for analogue inputs Mini B USB 2.0 connector for a programming terminal
  • Electrical durability 100000 cycles AC-12, 120 V, 240 VA, resistive 100000 cycles AC-12, 240 V, 480 VA, resistive 300000 cycles AC-12, 120 V, 80 VA, resistive 300000 cycles AC-12, 240 V, 160 VA, resistive 100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive 100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive 300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive 300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive 100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive 100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive 300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive 300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive 100000 cycles DC-12, 24 V, 48 W, resistive 300000 cycles DC-12, 24 V, 16 W, resistive 100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms) 300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms)
  • Exct time for event task 60 µs response time
  • Execution time for 1 KInstruction 0.3 ms for event and periodic task
  • Execution time per instruction 0.2 µs Boolean
  • Height 90 mm
  • Input impedance 3.4 kOhm for discrete input 100 kOhm for analog input 4.9 kOhm for fast input
  • Inrush current 40 A
  • Insulation Between input and internal logic at 500 V AC Non-insulated between analogue input and internal logic Non-insulated between analogue inputs Between supply and ground at 1500 V AC Between sensor power supply and ground at 500 V AC Between input and ground at 500 V AC Between output and ground at 1500 V AC Between supply and internal logic at 2300 V AC Between sensor power supply and internal logic at 500 V AC Between output and internal logic at 2300 V AC Between Ethernet terminal and internal logic at 500 V AC Between supply and sensor power supply at 2300 V AC
  • Integrated connection type USB port with mini B USB 2.0 connector Non isolated serial link serial 1 with RJ45 connector and RS485 interface Non isolated serial link serial 2 with RJ45 connector and RS232/RS485 interface
  • Local signalling 1 LED (green) for PWR 1 LED (green) for RUN 1 LED (red) for module error (ERR) 1 LED (green) for SD card access (SD) 1 LED (red) for BAT 1 LED (green) for SL1 1 LED (green) for SL2 1 LED per channel (green) for I/O state
  • LSB value 10 mV
  • marking CE
  • Maximum cable distance between devices Shielded cable: <10 m for fast input Unshielded cable: <30 m for output Unshielded cable: <30 m for digital input Unshielded cable: <1 m for analog input
  • Maximum current per output common 6 A at COM 1 7 A at COM 0
  • Maximum number of I/O expansion module 4 (local I/O-Architecture) 11 (remote I/O-Architecture)
  • Maximum power consumption in VA 46 VA at 100...240 V with max number of I/O expansion module 31 VA at 100...240 V without I/O expansion module
  • Maximum size of object areas 512 %KW constant words 512 %M memory bits 255 %C counters 8000 %MW memory words 255 %TM timers
  • Mechanical durability 20000000 cycles for relay output
  • Memory capacity 256 kB for user application and data RAM with 10000 instructions 256 kB for internal variables RAM
  • Minimum load 1 mA at 5 V DC for relay output
  • Mounting support Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 rail conforming to IEC 60715 plate or panel with fixing kit
  • Net weight 0.346 kg
  • network frequency 50/60 Hz
  • Output voltage limits 125 V DC 277 V AC
  • Permitted overload on inputs +/- 30 V DC for 5 min (maximum) for analog input +/- 13 V DC (permanent) for analog input
  • Power supply output current 0.325 A 5 V for expansion bus 0.12 A 24 V for expansion bus
  • Protection type Without protection at 5 A
  • Realtime clock With
  • Regulation loop Adjustable PID regulator up to 14 simultaneous loops
  • Reset time 1 s
  • Response time 35 µs turn-off, I2...I5 terminal(s) for input 10 ms turn-on for output 10 ms turn-off for output 5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input 35 µs turn-on, other terminals terminal(s) for input 5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input 100 µs turn-off, other terminals terminal(s) for input
  • Sensor power supply 24 V DC at 250 mA supplied by the controller
  • Supply (serial)serial link supply: 5 V, <200 mA
  • Supply voltage limits 85…264 V
  • Switching frequency 20 switching operations/minute with maximum load
  • Transmission rate 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 480 Mbit/s for USB
  • Voltage state 0 guaranteed <= 5 V for input
  • Voltage state 1 guaranteed >= 15 V for input
  • Width 95 mm
  • Environment

  • Ambient air temperature for operation -10…55 °C (horizontal installation) -10…35 °C (vertical installation)
  • Ambient air temperature for storage -25…70 °C
  • Electromagnetic emission Conducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to IEC 55011 Conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to IEC 55011 Conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10…150 kHz conforming to IEC 55011 Conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to IEC 55011 Radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to IEC 55011 Conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to IEC 55011 Radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to IEC 55011
  • Environmental characteristic Ordinary and hazardous location
  • Immunity to microbreaks 10 ms
  • IP degree of protection IP20 with protective cover in place
  • Operating altitude 0...2000 m
  • Pollution degree <= 2
  • Product certifications RCM ABS LR DNV-GL EAC cULus CE UKCA cULus HazLoc
  • Relative humidity 10…95 %, without condensation (in operation) 10…95 %, without condensation (in storage)
  • Resistance to conducted disturbances 10 V 0.15...80 MHz conforming to IEC 61000-4-6 3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL) 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
  • Resistance to electromagnetic fields 10 V/m 80 MHz...1 GHz conforming to IEC 61000-4-3 3 V/m 1.4 GHz...2 GHz conforming to IEC 61000-4-3 1 V/m 2...2.7 GHz conforming to IEC 61000-4-3
  • Resistance to electrostatic discharge 8 kV in air conforming to IEC 61000-4-2 4 kV on contact conforming to IEC 61000-4-2
  • Resistance to fast transients 2 kV (power lines) conforming to IEC 61000-4-4 2 kV (relay output) conforming to IEC 61000-4-4 1 kV (I/O) conforming to IEC 61000-4-4 1 kV (Ethernet line) conforming to IEC 61000-4-4 1 kV (serial link) conforming to IEC 61000-4-4
  • Resistance to magnetic fields 30 A/m 50/60 Hz conforming to IEC 61000-4-8
  • Shock resistance 98 m/s² for 11 ms
  • Standards IEC 61131-2 UL 508 CAN/CSA C22.2 No. 213 IACS E10 ANSI/ISA 12-12-01
  • Storage altitude 0…3000 m
  • Surge withstand 2 kV power lines (AC) common mode conforming to IEC 61000-4-5 2 kV relay output common mode conforming to IEC 61000-4-5 1 kV I/O common mode conforming to IEC 61000-4-5 1 kV shielded cable common mode conforming to IEC 61000-4-5 0.5 kV power lines (DC) differential mode conforming to IEC 61000-4-5 1 kV power lines (AC) differential mode conforming to IEC 61000-4-5 1 kV relay output differential mode conforming to IEC 61000-4-5 0.5 kV power lines (DC) common mode conforming to IEC 61000-4-5
  • Vibration resistance 3.5 mm at 5…8.4 Hz on symmetrical rail 3.5 mm at 5…8.4 Hz on panel mounting 1 gn at 8.4…150 Hz on symmetrical rail 1 gn at 8.4…150 Hz on panel mounting
  • Packing Units

  • Number of Units in Package 1 1
  • Number of Units in Package 2 20
  • Number of Units in Package 3 240
  • Package 1 Height 10.6 cm
  • Package 1 Length 13.9 cm
  • Package 1 Weight 300.0 g
  • Package 1 Width 14.0 cm
  • Package 2 Height 30 cm
  • Package 2 Length 60 cm
  • Package 2 Weight 6.983 kg
  • Package 2 Width 40 cm
  • Package 3 Height 105.0 cm
  • Package 3 Length 80.0 cm
  • Package 3 Weight 162 kg
  • Package 3 Width 120.0 cm
  • Unit Type of Package 1 PCE
  • Unit Type of Package 2 S04
  • Unit Type of Package 3 P12