EASYLOGIC DM6200H VAF PF DPM NONC CL1.0

EASYLOGIC DM6200H VAF PF DPM NONC CL1.0

0 reviews 0 sold. Only 1 remain
0.00ريال
Product Code: METSEDM6000HCL10NC
Availability: In Stock
Viewed 555 times

Product Description

This digital panel meter is part of the EasyLogic Digital Panel Meter Series. The device is able to analyse the load and indicate current burden with a tricolor bar. Providing Class 1 active energy accuracy per IEC 62053-21 standard, the meter will measure voltage, current and power factor. The meter has a 4 digits, eight segments, 15 mm height and bright red LED display. Mechanical dimensions are 96 mm in width, 96 mm in height and 80 mm in depth, for a product weight of 400 g.

Item specifics

  • Main

  • Device short name DM6000H
  • Product name EasyLogic DM6X00H NC
  • Range EasyLogic
  • Product or component type VAF PF meter
  • Complementary

  • Accuracy class Class 1
  • Communication of data Reading of measurements Instantaneous and demand values Revolution speed All counters
  • Communication port protocol -
  • Connections - terminals Current circuit: screw clamp terminals (bottom) 2.08…3.31 mm² cable(s) Voltage circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s) Control circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s)
  • Counter functions Power interruption ON hour counting
  • Demand intervals 1 s
  • Depth Outside : 13 mm Panel : 49 mm
  • Device application Remote monitoring
  • Display colour Red
  • Display digits 12 digit(s) - 14.2 mm in height
  • Display type 8 segments LED
  • Electrical insulation class Class II
  • Flame retardance V-0 conforming to UL 94
  • Frequency measurement range 45…65 Hz
  • Height 96 mm
  • Installation category III
  • Local signalling Green LED: activity Red LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
  • Material Polycarbonate
  • Maximum power consumption in VA 4 VA at 240 V between phase and neutral
  • Maximum power consumption in W 2 W at 240 V
  • Measurement accuracy Frequency +/- 0.05 % Power factor +/- 0.01 Current +/- 1 % Voltage +/- 1 %
  • Measurement category Category III 480 V
  • Measurement current 5…6000 mA
  • Measurement voltage 35…480 V AC 50...60 Hz between phases 46…277 V AC 50...60 Hz between phase and neutral 277…999000 V AC 50...60 Hz with external VT
  • Messages display capacity 3 fields of 4 characters
  • Metering type Unbalance current Calculated neutral current Unbalance voltage Rotation speed Phase currents Voltage U21, U32, U13, V1, V2, V3 Frequency Average voltage Vavg Average current Iavg
  • mounting mode Flush-mounted
  • Mounting support Framework
  • Net weight 300 g
  • network frequency 50 Hz 60 Hz
  • Product Certifications CE conforming to IEC 61010-1 CULus conforming to UL 61010-1 CULus conforming to CSA C22.2 No 61010-1 C-Tick
  • Sampling rate 32 samples/cycle
  • Signal Current 0.005...10 A (impedance 0.3 MOhm)6 x
  • Standards IEC 61010-1:ed. 3 UL 61010-1:ed. 3
  • Tamperproof of settings Protected by access code
  • Tightening torque Current circuit: 0.9…1 N.m Philips No 2 screwdriver Voltage circuit: 0.9…1 N.m Philips No 2 screwdriver Control circuit: 0.9…1 N.m Philips No 2 screwdriver
  • Type of installation Indoor installation
  • Type of measurement Current Voltage Frequency RPM
  • type of network 2P + N 2P 3P + N 3P 1P + N
  • Width 96 mm
  • Wire stripping length Current circuit: 3.68 mm Voltage circuit: 7 mm Control circuit: 7 mm
  • [In] rated current 1 A 5 A
  • [Us] rated supply voltage 48...277 V AC 45...65 Hz 48...277 V DC
  • Environment

  • Ambient air temperature for operation -10…60 °C
  • Ambient air temperature for storage -20…70 °C
  • Electromagnetic compatibility Electrostatic discharge conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 Surge immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Magnetic field at power frequency conforming to IEC 61000-4-8 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 Emission tests conforming to FCC part 15 class A Emission tests conforming to FCC part 15 Subpart C Emission tests conforming to FCC part 15 Subpart E
  • IP degree of protection IP51 front: conforming to IEC 60529 IP30 body: conforming to IEC 60529
  • Operating altitude <= 2000 m
  • Overvoltage category III
  • Pollution degree 2
  • Relative humidity 5…95 % at 50 °C
  • Service life 7 year(s)
  • Packing Units

  • Number of Units in Package 1 1
  • Number of Units in Package 2 18
  • Number of Units in Package 3 144
  • Package 1 Height 8.700 cm
  • Package 1 Length 12.000 cm
  • Package 1 Weight 340.000 g
  • Package 1 Width 12.000 cm
  • Package 2 Height 30.000 cm
  • Package 2 Length 40.000 cm
  • Package 2 Weight 6.739 kg
  • Package 2 Width 30.000 cm
  • Package 3 Height 75.000 cm
  • Package 3 Length 80.000 cm
  • Package 3 Weight 60.960 kg
  • Package 3 Width 60.000 cm
  • Unit Type of Package 1 PCE
  • Unit Type of Package 2 S03
  • Unit Type of Package 3 P06

Write a review

Note: HTML is not translated!
    Bad           Good
EASYLOGIC DM6200H VAF PF DPM NONC CL1.0

EASYLOGIC DM6200H VAF PF DPM NONC CL1.0

0.00ريال