Categories
Cart
Account
Search
Recent View
Go to Top
All Categories
×
- Training
- Industrial Automation and Control
-
Low voltage protection devices
-
Motor protection devices
- Contactors & Reversing Contactors - EasyPact TVS
- Contactors & Reversing Contactors - TeSys D
- Contactors & Reversing Contactors - TeSys D capacitor
- Contactors & Reversing Contactors - TeSys F
- Contactors & Reversing Contactors - TeSys Giga
- Contactors & Reversing Contactors - TeSys K
- Contactors & Reversing Contactors - TeSys LE
- Electronic Over Current Relays - Easy TeSys Protect
- Electronic Overload Relays - EOCR
- Motor management system - TeSys island
- Motor protection circuit breakers - Easy TeSys Power GZ
- Motor protection circuit breakers - TeSys GV2
- Motor protection circuit breakers - TeSys GV3
- Motor protection circuit breakers - TeSys GV4
- Thermal Overload Relays - TeSys Giga
- Thermal Overload Relays - TeSys LR9
- Thermal Overload Relays - TeSys LRD
- Relays and industrial accessories
-
Circuit Breakers and Switches
- Air Circuit Breakers - EasyPact MVS
- Air Circuit Breakers - MasterPact MTZ
- Air Circuit Breakers - MasterPact NW
- Miniature Circuit Breakers - Acti 9 C120
- Miniature Circuit Breakers - Acti 9 iC60
- Miniature Circuit Breakers - Acti 9 iK60
- Miniature Circuit Breakers - Residental Domae
- Miniature Circuit Breakers - Residental Resi9
- Molded Case Circuit Breakers - ComPacT INS
- Molded Case Circuit Breakers - ComPacT NS
- Molded Case Circuit Breakers - ComPacT NSX
- Molded Case Circuit Breakers - Easy CVS
- Molded Case Circuit Breakers - Easy GoPact
- Molded Case Circuit Breakers - Easy GoPact MTS
- Residual current devices - Acti 9 iC60 RCBO
- Residual current devices - Acti 9 iID RCCB
- Residual current devices - Vigi for iC60
- Power Quality and Power Factor Correction
-
Motor protection devices
-
Power supplies & Energy monitoring system
-
Energy meters & supplies
- Advanced metering
- Current Transformers
- EasyLogic DM6000H series VAF PF meters
- EasyLogic PM2000 Power Meters
- Industrial Power supplies - (ABLM / ABLS / ABL8)
- PowerLogic PM3000 Power Meters
- PowerLogic PM5000 Power Meters
- Single phase power supplies - Easy Modicon ABL2
- Temperature controller
- Transformers - Modicon ABT7, ABL6
-
Energy meters & supplies
- Control station & joysticks
- Secure Power
- Enclosures
Shopping Cart
×
Your shopping cart is empty!
Search
×
Recent View Products
×
Item specifics
-
Main
- Range of product Zelio Logic
- Product or component type Compact smart relay
-
Complementary
- Analogue input number 4
- Analogue input range 0...10 V 0...12 V
- Analogue input resolution 8 bits at maximum voltage
- Analogue input type Common mode
- Backup time 10 years at 25 °C
- Checks Program memory on each power up
- Clock With
- Clock drift 12 min/year at 0…55 °C 6 s/month at 25 °C
- Connections - terminals Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) semi-solid Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) solid Screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) solid Screw terminals, 2 x 0.25...2 x 0.75 mm² (AWG 24...AWG 18) flexible with cable end
- Contacts type and composition NO for relay output
- Conversion error +/- 5 % at 25 °C for analogue input circuit +/- 6.2 % at 55 °C for analogue input circuit
- Conversion time Smart relay cycle time for analogue input circuit
- Counting frequency 1 kHz for discrete input
- Current state 0 guaranteed <= 0.2 mA (IB...IG used as discrete input circuit) <= 0.9 mA (I1...IA and IH...IR discrete input circuit)
- Current state 1 guaranteed >= 2 mA (I1...IA and IH...IR discrete input circuit) >= 0.5 mA (IB...IG used as discrete input circuit)
- Cycle time 6…90 ms
- Discrete input current 4 mA
- Discrete input number 8 conforming to IEC 61131-2 Type 1
- Discrete input type Resistive
- Discrete input voltage 12 V DC
- Electrical durability AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to IEC 60947-5-1 AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to IEC 60947-5-1 DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to IEC 60947-5-1 DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to IEC 60947-5-1
- Input compatibility 3-wire proximity sensors PNP for discrete input
- Input impedance 14 kOhm for IB...IG used as analogue input circuit 14 kOhm for IB...IG used as discrete input circuit 2.7 kOhm for I1...IA and IH...IR discrete input circuit
- Local display With
- LSB value 39 mV for analogue input circuit
- Maximum permissible voltage 14.4 V for analogue input circuit
- Maximum supply current 120 mA (without extension)
- Mechanical durability 10000000 cycles for relay output
- Net weight 0.25 kg
- Number of outputs 4 relay
- Number or control scheme lines 0…240 with ladder programming 0…500 with FBD programming
- Operating distance 10 m between stations, with screened cable (sensor not isolated) for analogue input circuit
- Operating rate in Hz 0.1 Hz (at Ie) for relay output 10 Hz (no load) for relay output
- Output thermal current 8 A for all 4 outputs for relay output
- Output voltage limits 24...250 V AC (relay output) 5...30 V DC (relay output)
- Overvoltage category III conforming to IEC 60664-1
- Power dissipation in W 1.5 W without extension
- Repeat accuracy +/- 2 % at 55 °C for analogue input circuit
- Response time 10 ms (from state 0 to state 1) for relay output 5 ms (from state 1 to state 0) for relay output
- Reverse polarity protection With
- Supply voltage limits 10.4…14.4 V
- Switching capacity in mA >= 10 mA at 12 V (relay output)
- Tightening torque 0.5 N.m
- Voltage state 0 guaranteed <= 3 V for IB...IG used as discrete input circuit <= 2.4 V for I1...IA and IH...IR discrete input circuit
- Voltage state 1 guaranteed >= 7 V for IB...IG used as discrete input circuit >= 5.6 V for I1...IA and IH...IR discrete input circuit
- [Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
- [Us] rated supply voltage 12 V DC
-
Environment
- Ambient air temperature for operation -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2 -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
- Ambient air temperature for storage -40…70 °C
- Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1
- Environmental characteristic EMC directive conforming to IEC 61000-6-2 EMC directive conforming to IEC 61000-6-3 EMC directive conforming to IEC 61000-6-4 EMC directive conforming to IEC 61131-2 zone B Low voltage directive conforming to IEC 61131-2
- Immunity to microbreaks 1 ms repeated 20 times
- IP degree of protection IP20 (terminal block) conforming to IEC 60529 IP40 (front panel) conforming to IEC 60529
- Maximum altitude transport 3048 m
- Operating altitude 2000 m
- Pollution degree 2 conforming to IEC 61131-2
- Product certifications C-Tick UL CSA GOST GL
- Relative humidity 95 % without condensation or dripping water
- Standards IEC 61000-4-11 IEC 60068-2-6 Fc IEC 61000-4-12 IEC 61000-4-2 level 3 IEC 61000-4-5 IEC 61000-4-3 IEC 61000-4-4 level 3 IEC 60068-2-27 Ea IEC 61000-4-6 level 3
-
Packing Units
- Number of Units in Package 1 1
- Number of Units in Package 2 30
- Package 1 Height 6.8 cm
- Package 1 Length 10.0 cm
- Package 1 Weight 239.0 g
- Package 1 Width 9.0 cm
- Package 2 Height 30.0 cm
- Package 2 Length 40.0 cm
- Package 2 Weight 7.775 kg
- Package 2 Width 30.0 cm
- Unit Type of Package 1 PCE
- Unit Type of Package 2 S03
-
Contractual warranty
- Warranty 18 months